Datasheet

13
TS 46365 OSRAM / POWERSTAR HQI 106_T001_GB 2/22.04.2009
®
UV
FILTER
1 2
POWERSTAR
®
HQI
®
-E for open luminaires
HQI-E HQI-E HQI-E HQI-E
100 W 100 W 100 W 100 W
WDL WDL NDL NDL
clear coated clear coated
for open luminaires for open luminaires for open luminaires for open luminaires
Lamp reference HQI-E HQI-E HQI-E HQI-E
100W/WDL clear 100W/WDL coated 100W/NDL clear 100W/NDL coated
Nominal luminous flux lm 8500 7900 8400 7700
Luminous efficacy lm/W 85 79 84 77
Light colour/Colour appearance WDL WDL NDL NDL
Colour temperature K 3000 2900 4200 4000
Colour rendering index R
a
70 70 85 85
Lamp wattage W 100 100 100 100
Lamp voltage V 95 95 95 95
Lamp current A 1.1 1.1 1.1 1.1
Ignition voltage min./max. kVs 3.6/5 3.6/5 3.6/5 3.6/5
Base E27 E27 E27 E27
Diameter d mm 55 55 55 55
Length max. I mm 144 144 144 144
LCL a mm 92 92
Burning position universal universal universal universal
Average lamp life h 9000 9000 6000 6000
Max. perm. outer bulb temp. °C 330 330 330 330
Max. perm. base edge temp. °C 210 210 210 210
PF corr. cap. at 50 Hz µF 16 16 16 16
EAN 4050300351537 4050300351551 4050300345871 4050300345833
Standard pack Qty 20 20 20 20
Figure No. 1 2 1 2
Circuit (see page 22) Fig. no. 2 2 2 2
ILCOS MCS/UB-100/30/ MES/UB-100/29/ MCS/UB-100/42/ MES/UB-100/40/
2A-H-E27-55/144 2A-H-E27-55/144 1B-H-E27-55/144 1B-H-E27-55/144
Survival rate HQI-E 100/WDL
10000
100
80
60
40
20
0
Survival rate in %
Hours burned
2000 3000 4000 5000 6000 7000 8000 9000
Luminous flux behaviour HQI-E 100/WDL
10000
100
80
60
40
20
0
Luminous flux in %
Hours burned
2000 3000 4000 5000 6000 7000 8000 9000
Survival rate in %
Survival rate HQI-E 100/NDL
10000
100
80
60
40
20
0
Hours burned
2000 3000 4000 5000 6000
Luminous flux behaviour HQI-E 100/NDL
10000
100
80
60
40
20
0
Hours burned
2000 3000 4000 5000 6000
Luminous flux in %