Datasheet

CFL SQUARE
®
4-Pin & QUICKTRONIC
®
GL LB EU&LM FT, Edition: 26.02.2014. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded no guarantee will be provided.
TECHNICAL INFORMATION 03
Lamps oparated with HF
3
reference control gear at 25 °C (100 h agged) ambient temperature
CFL SQUARE
®
4- Pin
Lamp Voltage
rated
[V]
Lamp Current
rated
[mA]
Lamp Power
rated
[W]
CFL SQUARE
®
4-Pin 16W
84
180
15
CFL SQUARE
®
4-Pin 28W
97
260
24.5
CFL SQUARE
®
4-Pin 38W
96
355
34.5
Circuit (for CCG operation)
CFL SQUARE
®
4- Pin
External Starter
16 W, 28 W, 38 W
ST 111 LONGLIFE
Photometrical Data at 25 °C (100 h agged) ambient temperature
4
CFL
SQUARE
®
4- Pin
Light Color
LUMILUX
®
Color
Rendering
Index (CRI),
Ra
Target
Color
Coordinate
X
Target
Color
Coordinate
Y
Nominal
Luminous
Flux
[lm]
Efficacy
25 °C
[lm/W]
Energy
Effi-
ciency
Class
16 W
827 INTERNA
80 … 89
0.463
0.420
1050
66
B
16 W
835 White
80 … 89
0.409
0.394
1050
66
B
28 W
827 INTERNA
80 … 89
0.463
0.420
2050
73
B
28 W
835 White
80 … 89
0.409
0.394
2050
73
B
38 W
827 INTERNA
80 … 89
0.463
0.420
2735
71
B
38 W
835 White
80 … 89
0.409
0.394
2735
71
B
Relative Luminous Flux / Ambient Temperature
For more detailed information please refer to our technical guide Compact Fluorescent Lamps. Free
download at www.osram.com
3
High Frequency
4
Measurement in accordance with IEC 60901, annex C and the relevant annex on rated colour characteristics in IEC 60081.