User guide

STEP4:IFLOCALCODEREQUIRESTHEUSEOF
CABLES/WIRESTOSECURETHELUMINAIRETOBUILDING
STRUCTURE,USETHE4HOLESONTHEADJACENTTOTHE
EARTHQUAKECLIPS.
STEP5:
REMOVETHEJUNCTIONBOXCOVERTOACCESSTHE
WHITEANDBLACKLEADSONTHERIGHTHANDSIDEOFTHE
JUNCTIONBOX.
JUNCTIONBOXSIDEFORPRIMARYPOWERCONN ECTION
STEP6:
REMOVETHEDESIREDTRADESIZEKNOCKOUTAND
CONNECTTHELINEPOWERCONDUITCABLESASSHOWNIN
WIRINGDIAGRAMBELOW.REINSTALLTHEJUNCTIONBOX
COVER.
GREENGROUND
WHITENEUTRAL
BLACKHOT
PURPLE010VDIMMINGCONTROL(+)
GREY010VDIMMINGCONTROL()

STEP7:IFDIMMINGISREQUIRED.REMOVETHELEFTHAND
JUNCTIONBOXCOVERANDCONNECTTHE010VDIMMING
WIRESASSHOWNINTHEBELOWWIRINGDIAGRAM.
PURPLEANDGREYWIRESWILLBECAPPEDOFF.DONOT
REMOVECAPSIFTHEYWILLNOTBECONNECTEDTOA
DIMMINGSYSTEM.
JUNCTIONBOX
SIDEFORCONNECTING010VDIMMING
LEADS
STEP8:
AFTERCONNECTINGDIMMINGLEADSREINSTALL
THEJUNCTIONBOXCOVER.
SYLVANIA is a registered trademark of OSRAM SYLVANIA INC.
Specifications subject to change without notice
© 2012 OSRAM SYLVANIA Inc. 02/12