www.osram-os.com Produktdatenblatt | Version 1.1 LS P47F LS P47F PointLED ® With a diameter of just 2 mm, the PointLED is one of the smallest packages in its class and achieves high luminous efficacies. Due to its round and flat package, measuring only 0.775 mm high, it is ideal for application where space is a sensitive issue. Applications ——Ambient Light Sensors ——Interior Illumination (e.g.
LS P47F Ordering Information Type Luminous Intensity 1) IF = 30 mA Iv Mounting methode Ordering Code LS P47F-U2AA-1-3A5A 560 ... 1400 mcd Reverse Q65112A3009 LS P47F-U2AA-1-3A5A-F 560 ... 1400 mcd Top Q65112A3010 2 Version 1.
LS P47F Maximum Ratings Parameter Symbol Operating Temperature Top min. max. -40 °C 100 °C Storage Temperature Tstg min. max. -40 °C 100 °C Junction Temperature Tj max. 125 °C Forward current TS = 25 °C IF max. 50 mA Surge Current t ≤ 10 µs; D = 0.1 ; TS = 25 °C IFS max. 100 mA Reverse voltage 2) TS = 25 °C VR max. 12 V ESD withstand voltage acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) VESD 3 Version 1.
LS P47F Characteristics IF = 30 mA; TS = 25 °C Parameter Symbol Peak Wavelength λpeak typ. 645 nm Dominant Wavelength 3) IF = 30 mA λdom min. typ. max. 627 nm 633 nm 639 nm Spectral Bandwidth at 50% Irel,max ∆λ typ. 15 nm Viewing angle at 50 % IV 2φ typ. 120 ° Forward Voltage 4) IF = 30 mA VF min. typ. max. 1.80 V 2.20 V 2.55 V Reverse current 2) VR = 12 V IR typ. max. 0.01 µA 10 µA Temperature Coefficient of Peak Wavelength -10°C ≤ T ≤ 100°C TCλpeak typ. 0.
LS P47F Brightness Groups Group Luminous Intensity 1) IF = 30 mA min. Iv Luminous Intensity. 1) IF = 30 mA max. Iv Luminous Flux 6) IF = 30 mA typ. ΦV U2 560 mcd 710 mcd 1910 mlm V1 710 mcd 900 mcd 2420 mlm V2 900 mcd 1120 mcd 3030 mlm AA 1120 mcd 1400 mcd 3780 mlm Forward Voltage Groups Group Forward Voltage 4) IF = 30 mA min. VF Forward Voltage 4) IF = 30 mA max. VF 3A 1.80 V 1.95 V 3B 1.95 V 2.10 V 4A 2.10 V 2.25 V 4B 2.25 V 2.40 V 5A 2.40 V 2.
LS P47F Group Name on Label Example: AA-1-3A Brightness Wavelength Forward Voltage AA 1 3A 6 Version 1.
LS P47F Relative Spectral Emission 6) Irel = f (λ); IF = 30 mA; TS = 25 °C Irel LS P47F 1,0 : Vλ : super red 0,8 0,6 0,4 0,2 0,0 350 400 450 500 550 600 650 700 750 800 λ [nm] Radiation Characteristics 6) Irel = f (ϕ); TS = 25 °C LS P47F ϕ [°] -20° -40° -50° -10° 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 1,0 -30° 0,8 0,6 -60° -70° -80° -90° -100° 7 Version 1.
LS P47F Forward current Relative Luminous Intensity 6), 7) IF = f(VF); TS = 25 °C IF [mA] 6), 7) Iv/Iv(30 mA) = f(IF); TS = 25 °C LS P47F IV LS P47F 50 IV(30mA) 1,6 1,4 40 1,2 1,0 30 0,8 20 0,6 0,4 10 0,2 VF [V] 8 Version 1.
LS P47F Forward Voltage Relative Luminous Flux 6) Iv/Iv(25 °C) = f(Tj); IF = 30 mA ∆VF = VF - VF(25 °C) = f(Tj); IF = 30 mA ∆VF [V] LS P47F 0,3 6) Φv LS P47F 1,6 Φv(25°C) 1,4 0,2 1,2 0,1 1,0 0,0 0,8 0,6 -0,1 0,4 -0,2 0,2 -0,3 -40 -20 0 20 40 60 80 100 120 Tj [°C] 9 Version 1.
LS P47F Max. Permissible Forward Current IF = f(T) IF OHL02708 60 mA 50 TS 40 TA 30 20 10 0 TA temp. ambient TS temp. solder point 0 20 60 40 80 ˚C 100 T Permissible Pulse Handling Capability Permissible Pulse Handling Capability IF = f(tp); D: Duty cycle; TS = 25 °C IF = f(tp); D: Duty cycle; TS = 85 °C OHL02706 0.12 IF A 0.10 0.2 0.08 0.5 0.06 D= 0.005 0.01 0.02 0.05 0.1 D= 0.10 0.005 0.01 0.02 0.05 0.1 0.2 0.08 0.5 0.06 1 0.04 0.02 OHL02707 0.12 IF A 1 0.
LS P47F Dimensional Drawing 8) Approximate Weight: 6.0 mg Corrosion test: Class: 3B Test condition: 40°C / 90 % RH / 15 ppm H2S / 14 days (stricter then IEC 60068-2-43) 11 Version 1.
LS P47F Recommended Solder Pad 8) For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Recommended Solder Pad 8) For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. 12 Version 1.
LS P47F Reflow Soldering Profile Product complies to MSL Level 2 acc.
LS P47F Taping 8) 14 Version 1.
LS P47F Taping 8) 15 Version 1.
LS P47F Tape and Reel 9) Reel dimensions [mm] A W Nmin W1 W2 max Pieces per PU 180 mm 8 + 0.3 / - 0.1 60 8.4 + 2 14.4 3000 330 mm 8 + 0.3 / - 0.1 60 8.4 + 2 14.4 12000 16 Version 1.
LS P47F Barcode-Product-Label (BPL) Dry Packing Process and Materials 8) Moisture-sensitive label or print Barcode label L VE LE see lab e If nk, bla cod bar hu ve y el . H) (R dit mi e ed ag % . RH /60 ˚C rar ck rel 30 N s VE RS inf pa % ainITI TO of to ak 90 d ntNSUC < ns (pe or TIO d , cte itio an bje ing U g coSEND ˚C nd 5 ˚C su ss CO Ais baRE co ± ce y 40 be TU MI CThIS ˚C < ll pro tor SE ati _ < ). urs urs Ho de urs Ho co 72 Ho urs te 48 e Ho 24 6 da e tim e th tim or ).
LS P47F Transportation Packing and Materials 8) DE R 18 -1 -1 +Q P OU P: 44 01 C: 99 8 D/ 20 00 (9 D) 210 021 : 34 O H 12 (Q )Q TY : S S em R ic AM o nd O uc p to to H rs NO TC BA 3G 5 14 2 (6 P) NO : 12 T 11 00 LO (1 T) NO : OD M Y DE -1 18 P -1 + Q R G RO UP : (G ) 44 01 D/ C: (9 D) 0 AM 00 TY :2 )Q O SR 34 NO : (X ) PR O D 5 14 2 110 0 (Q A R ic NO : O S em S (1 T) LO T NO (6 P) : 12 3G BA TC H H 12 o M n O d u p ct to o rs M Muster
LS P47F Type Designation System Wavelength (λdom typ.
LS P47F Notes The evaluation of eye safety occurs according to the standard IEC 62471:2006 (photo biological safety of lamps and lamp systems). Within the risk grouping system of this IEC standard, the device specified in this data sheet falls into the class exempt group (exposure time 10000 s). Under real circumstances (for exposure time, conditions of the eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices.
LS P47F Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization.
LS P47F Glossary 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ±8 % and an expanded uncertainty of ±11 % (acc. to GUM with a coverage factor of k = 3). 2) Reverse Operation: Reverse Operation of 10 hours is permissible in total. Continuous reverse operation is not allowed. 3) Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ±0.
LS P47F Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. 23 Version 1.