Potential Replacement
The proposed most similiar alternatives have no difference in terms of dimensions.
The only difference is in a change of the spectral sensitivity:
F-type filter have a close match for 950 nm emitter but a poor match for the 850nm
FA-type filter are matching very good for 850 nm and 950 nm emitters
FA-type filter show a higher ambient light sensitivity than F-type filter due to the wider
sensitivity range towards visible wavelengths
Our Application Team will strongly support you with any further question concerning your
specific application. Please contact your Account Manager.
0
10
20
30
40
50
60
70
80
90
100
400 500 600 700 800 900 1000 1100
Srel (%)
lambda (nm)
950nmEmitter 850nm
“FA” filter detector
alternative
“F” filter detector
affected device
wavelength (nm)
relative spectral sensitivity (%)