Certifications 2

dimethyl carbonate
Not Available
Not Available
lithium fluorophosphate
250 mg/m3
Not Available
aluminium
Not Available
Not Available
OCCUPATIONAL EXPOSURE BANDING
Ingredient
Occupational Exposure Band Rating
Occupational Exposure Band Limit
ethylene carbonate
E
≤ 0.01 mg/m³
Notes:
Occupational exposure banding is a process of assigning chemicals into specific categories or bands based on a chemical's potency and the
adverse health outcomes associated with exposure. The output of this process is an occupational exposure band (OEB), which corresponds to a
range of exposure concentrations that are expected to protect worker health.
MATERIAL DATA
Exposure controls
Appropriate engineering
controls
General exhaust is adequate under normal operating conditions.
Provide adequate ventilation in warehouse or closed storage areas.
Personal protection
Eye and face protection
Safety glasses with unperforated side shields may be used where continuous eye protection is desirable, as in laboratories; spectacles are
not sufficient where complete eye protection is needed such as when handling bulk-quantities, where there is a danger of splashing, or if the
material may be under pressure.
Chemical goggles.whenever there is a danger of the material coming in contact with the eyes; goggles must be properly fitted.
Full face shield (20 cm, 8 in minimum) may be required for supplementary but never for primary protection of eyes; these afford face
protection.
Alternatively a gas mask may replace splash goggles and face shields.
Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants. A written policy document, describing
the wearing of lenses or restrictions on use, should be created for each workplace or task. This should include a review of lens absorption
and adsorption for the class of chemicals in use and an account of injury experience. Medical and first-aid personnel should be trained in
their removal and suitable equipment should be readily available. In the event of chemical exposure, begin eye irrigation immediately and
remove contact lens as soon as practicable. Lens should be removed at the first signs of eye redness or irritation - lens should be removed in
a clean environment only after workers have washed hands thoroughly. [CDC NIOSH Current Intelligence Bulletin 59], [AS/NZS 1336 or
national equivalent]
Skin protection
See Hand protection below
Hands/feet protection
Wear protective gloves, e.g. PVC.
Body protection
See Other protection below
Other protection
Overalls.
P.V.C. apron.
Barrier cream.
Skin cleansing cream.
Eye wash unit.
Respiratory protection
Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent)
Where the concentration of gas/particulates in the breathing zone, approaches or exceeds the "Exposure Standard" (or ES), respiratory protection is required.
Degree of protection varies with both face-piece and Class of filter; the nature of protection varies with Type of filter.
Required Minimum Protection Factor
Half-Face Respirator
Full-Face Respirator
Powered Air Respirator
up to 10 x ES
A-AUS
-
A-PAPR-AUS / Class 1
up to 50 x ES
-
A-AUS / Class 1
-
up to 100 x ES
-
A-2
A-PAPR-2 ^
^ - Full-face
A(All classes) = Organic vapours, B AUS or B1 = Acid gasses, B2 = Acid gas or hydrogen cyanide(HCN), B3 = Acid gas or hydrogen cyanide(HCN), E = Sulfur dioxide(SO2), G =
Agricultural chemicals, K = Ammonia(NH3), Hg = Mercury, NO = Oxides of nitrogen, MB = Methyl bromide, AX = Low boiling point organic compounds(below 65 degC)
Respirators may be necessary when engineering and administrative controls do not adequately prevent exposures.
The decision to use respiratory protection should be based on professional judgment that takes into account toxicity information, exposure measurement data, and frequency and
likelihood of the worker's exposure - ensure users are not subject to high thermal loads which may result in heat stress or distress due to personal protective equipment (powered,
positive flow, full face apparatus may be an option).
Published occupational exposure limits, where they exist, will assist in determining the adequacy of the selected respiratory protection. These may be government mandated or
vendor recommended.
Certified respirators will be useful for protecting workers from inhalation of particulates when properly selected and fit tested as part of a complete respiratory protection program.
Use approved positive flow mask if significant quantities of dust becomes airborne.
Try to avoid creating dust conditions.
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
Appearance
Rectangular plastic casing with exposed terminals for electrical connections, odorless, solid battery.
Physical state
Manufactured
Relative density (Water = 1)
Not Available
Chemwatch:
5375-96
Version No:
3.1.1.1
Page
5
of
12
IS1500: 12V/6AH LITHIUM JUMPSTARTER
Issue Date:
22/11/2019
Print Date:
22/11/2019
Continued...