Prog_Card_Manual_V1.0
3. Autobind settings:
In autobind settings user can set the time when the receiver enters autobind mode if no signal from
already known (bound) transmitter is available. Available settings:
- Autobind OFF – Receiver never enters autobind mode. To avoid accidental binding with transmitter
nearby please use this mode when possible.
- Autobind 30 (60, 120)sec. – select timeout when receiver will enter an autobind mode. Please use this
mode carefully. In autobind mode receiver blinks red LED indicating this mode before it enters binding.
4. FailSafe settings.
All receivers are equipped with failsafe options. After missing transmitter signal for 1 second the
receiver enters failsafe mode. The channels states can be preprogrammed to make model act the most
safe way. There are several options for reaction in Fail Safe
- no packet – no output signals on servo channels at all.
- on bind – servo channels values will be same as coming from transmitter during binding
- all 1500 – all channels except throttle are 1500ms. Throttle is 1003ms(min)
- set current – remember the values currently coming from the Program Card. This option is used
in conjunction with Channels Menu. In channels menu you can set desirable values for your fail
safe. After this you can go to FailSafe menu and choose “set current”. The card will ask to store
values. After confirmation the values that currently set in Channels menu will be stored as Fail
Save values.