Min thr – Minimum throttle for ESC when the throttle stick is low
Max thr – Maximum throttle for ESC when the throttle stick is high
Min command – Minimum throttle for ESC during initial calibration on start.
Please note: If the model type is changed, all previous settings will be erased and set to default values.
You will need to set them again according to your needs.
7 Page 7. Accelerometer calibration
To calibrate an accelerometer:
1. Place the plane horizontally in exact position as it is supposed to be during the flight straight. The
plane should stay still and stable in this position. Do it indoor because wind will affect calibration
settings.
2. Enter Calibration menu. Confirm to start calibration process.
Please note that during calibration the stabilizer will be disconnected from the Programming Card for
short period of time. Do not touch or move your plane at this moment.
After calibrating is finished, the connection with the Programming Card will be restored and the
message «ACC ok» will appear on the top side of the screen.