3 Page 3 Flight setup.
Angle not ARM prevents ESC to arm if the model is tilted beyond set angle to the horizon (in degrees)
Angle envelop – limits the maximum angle of bank and tilt in Beginner mode to the horizon (in degrees).
FailSafe thr – Throttle level in FailSafe situation(signal loss).Acceptable values are 1000us...2000us. Keep
it low to stop the motor in signal loss event(about 1000-1100us).
FS off delay – delay to turn motor off in Fail Safe. In most cases keep it about 1second
4 Page 4 Servo output settings
Press Enter on dial to enter the menu. If you need to change the servo you want to set, press Enter again
and the cursor will highlight servo name (Ail, Rudd,etc). Press Enter again to exit from the servo
selection submenu.
Servo – name of channel, (Ail1, Ail2, Elev, Rudd) which will be set;
Min – Lowest servo endpoint (us). Range is 1000us…2000us
Mid – middle position of the servo (us). Changing this parameter you can subtrim servo in middle point.
Max – Highest servo endpoint (us). Range is 1000us…2000us
Rate – Rates of the servo output, %. Range is 0%…100%
Dir – servo direction, (Normal, Reversed)