Prog_Card_Manual_V1.0

Info tab
ORX
4
SERVO STABILIZER
(P322).”GEORGE”
1. Page 1 of PID settings.
Click the roller wheel to enter the menu You can chose the axis to change – ROLL, PITCH, YAW . Step on
the axis whose parameters you want to edit. Click Enter again. Now you can navigate between P, I and
D parameters. Click enter again. The edited parameter will start blinking. Use roller to change the value.
When value is changed press Enter again and exit the value changing mode. You can navigate to another
parameter and change their values if you need. After changes are done push roller UP several times to
exit to upper and upper levels and finally exit. The window will pop up asking if you want to save
changes. Choose what you want to do and click Enter on the roller. The changes will be transferred to