Specifications

Photometrics:
LED Wall Sconce
ELECTRICAL DATA
Input Voltage
Input Frequency
Input Current
Input Power
Power Factor
THD
FCC
Operating Temperature
Dimming
 V
 Hz
. A

Greater than .
<%
Meets FCC Title , Part  Class B
- °C to
Yes*
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.03021 PAGE: 4 OF 9
ISSUE DATE: 12/01/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P350113-108-30
DEG CANDELA LUMENS
0 375
5 372 35
15 353 99
25 314 145
35 263 164
45 202 156
55 142 127
65 90 90
75 50 53
85 19 22
90 9
95 3 4
105 3 3
115 3 3
125 2 2
135 1 1
145 1 1
155 0 0
165 0 0
175 0 0
180 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 279 30.9
0- 40 444 49.0
0- 60 727 80.3
0- 90 891 98.4
90-120 10 1.1
90-130 12 1.4
90-150 14 1.6
90-180 14 1.6
0-180 905 100.0
EFFICACY = 51.4 lm/W
CIE TYPE - DIRECT
SPACING CRITERION: 1.16
130
260
390
15˚ 30˚
45˚
60˚
75˚
90˚
LEGEND
0-deg
P--
LED Light Engine:  K  CRI CRI
System Wattage: 
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria:
CANDELA DISTRIBUTION
CANDELA DISTRIBUTION FLUX
. . . . .

  
   
   
   
   
   
   
   
  
   
   
   
   
   
   
  



701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 18.00104 PAGE: 7 OF 13
ISSUE DATE: 02/06/18
PREPARED FOR: PROGRESS
CATALOG NUMBER: P710051-009-30
CANDELA DISTRIBUTION FLUX
0.0 45.0 90.0 135.0 180.0
011111
5 112914 1
15 0 0 1 28 42 4
25 0 0 3 48 75 11
35 0 0 4 69 109 20
45 0 0 5 89 142 32
55 0 0 6 106 174 45
65007 118 200 56
75108 128 218 65
85007 131 227 69
90 0 0 8 132 228
95018 132 226 69
105007 124 213 63
115007 111 192 53
12500693 160 40
13501673 125 27
14500449 82 15
15500326 40 6
16510257 1
17500000 0
18000000
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 15 2.6
0- 40 35 6.1
0- 60 112 19.5
0- 90 302 52.4
90-120 185 32.1
90-130 225 39.1
90-150 268 46.5
90-180 275 47.6
0-180 576 100.0
EFFICACY = 35.1 lm/W
CIE TYPE - GENERAL DIFFUSE
PLANE : 0-DEG 90-DEG
LUMINOUS LENGTH : 1.500 1.500
HEIGHT OF SIDE :11.000 11.000
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG 0-DEG 90-DEG 180-DEG
45 0. 585. 16601.
55 0. 628. 18215.
65 0. 682. 19491.
75 94. 751. 20454.
85 0. 652. 21153.
110
220
110
220
15˚ 30˚ 45˚
60˚
75˚
90˚
105˚
120˚
135˚150˚165˚180˚
LEGEND
0-deg
90-deg
180-deg
LED Light Engine:  K  CRI
System Wattage: 
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria:
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 15 2.6
0-40 35 6.1
0-60 112 19.5
0-90 302 52.4
90-120 185 32.1
90-130 225 39.1
90-150 268 46.5
90-180 275 47.6
0-180 576 100.0
CANDELA DISTRIBUTION
CANDELA DISTRIBUTION FLUX
. . . . .

  
   
   
   
   
   
   
   
  
   
   
   
   
   
   
  



Test . Test Date //