No. AJFS1809009217FF  Date: OCT.17, 2018  Page 3 of 6 
V.  SAMPLE DETAILS 
Sample description  PVC panel 
Color / Density  White / About 1.36 kg/m
2
Exposed face: 
The front face   
MOUNTING METHODS: 
The 20-gage, 2-in. (51-mm) hexagonal galvanized steel netting should span the width of the tunnel, then 
the specimen shall be placed on the netting 
The specimen consisted of 15 pieces of 500mm wide×500mm long x 25.0mm thickness and all sections 
jointed end- to- end. 
TEST RESULTS 
FSI  SDI 
10 
400 
RATING: 
The National Fire Protection Association  Life  Safety Code 101, Chapter 10,  Section 10.2.3 “Interior Wall 
and Ceiling Finish Classification”, has a means of classifying materials with respect to Flame Spread and 
Smoke  Developed  when  tested  in  accordance  with  NFPA  255,  ASTM  E84,  UL  723  “Method  of  Test  of 
Surface Burning Characteristics of Building Materials”. 
International  Building  Code,  Chapter  8,  Interior  Finishes,  Section  803  “Wall  and  Ceiling  Finishes”,  was 
classified in accordance with ASTM E 84 or UL 723. Such interior finish materials shall be grouped in the 
following classes in accordance with their flame spread and smoke-developed indexes. 
To be continued…. 