Figure 4-2 - Compact Outdoor Housing Dimensions
Note: The arrows in the illustration above indicate the openings for the mounting screws.
Note: If power supply is installed far from the nWGT unit, verify that there is no power line
leakage and that the unit receives correct voltage.
Notes:
Thread the cables through UL listed glands or appropriate metal tubing.
The large opening can host a gland for cables of a diameter between 5.8 mm /
0.230” to 13.9 mm / 0.530”, while the small openings are suitable for a diameter
between 2.9 mm / 0.114” to 6.4 mm / 0.250”. Tighten the glands in order to prevent
the intrusion of water or gases through conduits, cables and conductors.
Do not damage unit sealing (IP66 protection).
4.3. White Box Unit Installation
The following provides instructions for installing the nWGTWhite Box Unit.
20 nWGT Installation Manual