Installation Manual

Section 4 Installation
4.1. General
The following provides instructions for installing the nWGT unit.
There are two different installation units:
Compact Unit Installation
White Box Unit Installation
4.2. Compact Unit Installation
The following provides instructions for installing the Compact nWGTUnit.
4.2.1. Installation Instructions
To install Compact nWGTUnit, proceed as follows:
1. Remove the nWGT front panel
2. Remove the cable entry knockout plates:
For the DC unit, remove two panels in left side (one for LAN and one for Power cables)
For the AC unit remove one panel in the right side for the LAN cable (see Figure 4-1):
Figure 4-1 - Knockout Plates
a. Using a step drill bit, drill a 22.5 mm / 0.885" hole in diameter for the large knockout plate
and a 12.5 mm / 0.492" hole in diameter for the small knockout plate (if needed)
b. Thread the cables through a PG-16 gland (large knockout) and a PG-7 gland (small
knockout)
c. Tighten the glands to the box in order to prevent the intrusion of water or gases
18 nWGT Installation Manual