Installation Manual

4.2.1.2. Installation Procedure
To install the TR500 at any non-hazardous area of the fuel pump, proceed as follows:
1. Shut down any power source at the installation and working area
2. Select a non-hazardous area in the pump where you can install the TR500. The area should be a
flat panel with a thin metal panel where you can attach the TR500
3. Identify the prescribed location of the TR500 on the fuel pump housing. Draw a horizontal
reference line to allow correct alignment of the lower edge of the drilling template
4. Use the drilling template to mark the five holes on the mounting surface
5. Drill five 4 mm holes in accordance with the template
6. Drill the center hole to a diameter of 20mm
7. Thoroughly clean burrs on the hole edges
8. Inspect the hole and check for correct location according to the template
9. Clean the surface intended for installing the TR500
10. Use four M3 x 20 screws to attach and tighten the TR500 to the surface
4.2.2. Installation with Bracket on Top of Pump
The following table details the installation kit for installing the TR500 on the wall (see Table 4-1):
P/N Description Quantity
814327191 TR500 WALL INST BRACKET 1
815225300 SCREW, M3x10+SPRING& FLAT WASHER 2
815228300 USER MANUAL, TR500 1
Table 4-1 - Top/Wall Mounting Kit - P/N 819027190
The following shows the installation bracket (see Figure 4-2):
22 TR500 Installation and Setup Manual