Installation Manual

The connection must be either a socket into which a standard Ethernet patch cable can
be connected, or a cable that is terminated in a standard RJ45 plug suitable for direct
connection into the outdoor payment terminal's LAN socket
Minimum cable standard should be CAT5e STP(Shielded)
c. The enclosure may provide an alternative data connection for terminals that have optional
communications modules installed. Please consult with Orpak for what options are available
Accessibility
The enclosure must be designed and mounted so that disabled persons are able to operate the outdoor
payment terminal.
Materials
The enclosure and all its components must be constructed of durable materials suitable for the intended
location.
Water Tightness
The TR500 is rated for IP66. The parts sitting inside the pump / pedestal enclosure are designed to reduce
the likelihood of rain drops entering the electronics, but the enclosure must provide good protection from
water. The door should have a water seal against the enclosure, and there should also be drainage and /
or a system to reduce excessive condensation build-up and dripping.
3.4. Required Tools
The following tools are required to mount the TR500:
Torx T20 screw driver
Philips #1, or Flat 5 mm screw driver
Drill
Warning: Do NOT use power tools if working on a fuel station forecourt. Any spark could
cause an explosion.
TR500 Installation and Setup Manual 19