Installation Manual

Figure 3-1 - Dimensions
Fire
The enclosure must be designed to meet the requirements of ISO/EN 60950-1 for fire enclosures.
ATEX (Explosive Atmospheres)
ATEX (Explosive Atmospheres): The TR500 has openings that prevent it being gas-tight, and consequently
it must be located away from any hazardous zone. Refer to local laws and regulations for hazardous zones
to determine a suitable mounting arrangement for the TR500. The enclosure in which the TR500 is
mounted should also be designed to prevent a dangerous build-up ofexplosive gases.
Security
The enclosure must provide sufficient physical security to protect the public from the hazards within, as
well as reduce the possibility of tampering with the outdoor payment terminal.
Power & Data
a. The enclosure must provide mains power with the following requirements:
A permanently-wired connection or a socket
A protective earth connection
b. The enclosure must provide an Ethernet data connection with the following requirements:
Capable of at least 10Mbps (preferably 100Mbps)
18 TR500 Installation and Setup Manual