User's Manual

Page 14
Indicators
Fastfind (non-GPS version)
PLB SELF-TEST
Event
Self-test button pressed and held Self-test completed and passed
Red Light On while self-test sequence in
progress
(approx 8 seconds)
Off
Green
Light
Off Flashes 3 times
Buzzer Off Sounds 3 times
EMERGENCY OPERATION
First 2 minutes After 2 minutes
Event
Start/On button pressed 121.5MHz homing transmitter
on.
406 MHz burst transmission
Red Light On continuously for first 2
minutes
Flashes every 2.5 seconds
except during a 406 MHz
burst transmission
Off
Green
Light
Off Off Long flash for 2 seconds every 50
seconds, then off.
Buzzer Sounds approx every 2.5 seconds
DIAGNOSTIC INDICATIONS SPECIAL
MODES
Event
Self-test button
pressed and
held
Self-test
completed
During operation Protocol
Programming
Red Light Off Flashes 3
times
Does not flash Flashes every
2.5 seconds
Flashes
continually.
Green
Light
Off Off Long flash for 2 seconds
every 50 seconds, then
off.
Does not flash -
Buzzer Off Off - - -
Meaning
No power to PLB Self-test
failure
No 121.5MHz signal No 406 MHz
signal
Programming
mode.
Action
to be
taken
Check battery
pack is secure.
Replace battery
pack. Return unit
to dealer if
problem persists.
Do not use.
Return unit to
dealer.
None.
Unit is still broadcasting
406MHz signal.
None.
Unit is still
broadcasting
121.5MHz
signal.
Programming
can only be
carried out by an
authorised
dealer using
special
equipment.