Installation Manual

AIS Installation Manual Issue 1 39
7.4.26 VSD AIS voyage static data
This sentence may be output by the transponder in response to a query.
$--VSD,x.x,x.x,x.x,cc,hhmmss.ss,xx,xx,x.x,x.x*hh<CR><LF>
regional application flags
navigational status
estimated month of arrival at destination
estimated day of arrival at destination
estimated UTC of arrival at destination
destination
persons on-board
maximum present static draught
type of ship and cargo category
7.4.27 VTG course over ground and ground speed
This sentence contains the actual course and speed relative to the ground.
$--VTG,x.x,T,x.x,M,x.x,N,x.x,K,a*hh<CR><LF>
mode indicator
speed over ground, km/h (ignored)
speed over ground, knots
course over ground, degrees magnetic (ignored)
course over ground, degrees true
Note that RMC has priority over VTG.
.
7.4.28 VSD AIS voyage static data
This sentence is output by the transponder in response to a query and contains the Ship’s
voyage data.
$--VSD,x.x,x.x,x.x,cc,hhmmss.ss,xx,xx,x.x,x.x*hh<CR><LF>
regional application flags
navigational status
estimated month of arrival at destination
estimated day of arrival at destination
estimated UTC of arrival at destination
destination
persons on-board
maximum present static draught
type of ship and cargo category
7.5 General faults & error messages
An ALR-sentence is used to indicate a failure or malfunction that will significantly reduce
integrity or stop operation of M2. The Alarm messages generated are IEC61162-1 compliant
“$AIALR”-sentences on the Presentation Interface output ports.
The parameters of this sentence are:
Time of alarm condition change (UTC)
Unique alarm number (identifier) at alarm source
Alarm condition
Alarm acknowledge state
Alarm description text
and are set according to the table following.
The "alarm condition" field is set to "A" when the alarm condition threshold is exceeded, and "V"
when the alarm condition returns to a level that does not exceed the threshold. A continuing
healthy status “V” is sent out at 1 minute intervals.
NOTE: When all alarm conditions are healthy, a special single message is sent at 1 minute
intervals.