Operation Manual
www.orion.ua
6
damage the cooler.
FUSE BLOWOUT
Replace the broken fuse with the attached spare fuse by completing the following steps:
1) Pull out the plastic cap by removing the screw using a screwdriver.
2) Remove the blown fuse and replace with the new fuse.
3) Fasten the screw and put the plastic cap in place.
TECHNICAL DATA
Capacity: 16L
Weight: 3.2kg
Application: 12V DC, 220-240V AC, ~50Hz
Rated current: 6A
Power input: 46W (cool)/ 41W (warm)
Cooling capacity: Max 17-23 degrees below ambient temperature
Heating capacity: Max 50-65degrees
Insulation: Solid polyurethane foam
Cooling unit: Thermo electric element
TROUBLESHOOTING
If the unit does not operate correctly:
1. Make sure that the contacts in the 12V socket are clean.
2. Make sure the 12V plug is properly connected in the 12V power source.
3. Make sure are no obstructions in or near the fan that may affect its operation.
4. Make sure the unit is well ventilated and not stored in a closed area such as a car
boot.
COMPLETION
Cooler and Warmer, Auto adapter 12V, Adapter 220V/12V (optional), User Manual,
Warranty Card