User Guide
Chapter 2 Simulation examples
44
To set up and run a parametric analysis to step the value of R1
using Rval
1 From Capture’s PSpice menu, choose
New Simulation Profile.
The New Simulation dialog box appears.
2 In the Name text box, type
Parametric.
3 From the Inherit From list, select AC Sweep, then click
Create.
The Simulation Settings dialog box appears.
4 Click the Analysis tab.
5 Under Options, select Parametric Sweep and enter the
settings as shown below.
Figure 23 Parametric simulation settings.
6 Click OK.
7 From the PSpice menu, choose Run to start the
analysis.
T
h
e root sc
h
ematic
l
iste
d
is t
h
e sc
h
ematic
page associated with the simulation profile
you are creating.
This profile specifies that the parameter
Rval is to be stepped from 100 to 10k
logarithmically with a resolution of 10
points per decade.
The analysis is run for each value of Rval.
Because the value of R1 is defined as
{Rval}, the analysis is run for each value of
R1 as it logarithmically increases from
100
Ω to 10 kΩ in 20 steps, resulting in a
total of 21 runs.
Pspug.book Page 44 Wednesday, November 11, 1998 1:14 PM