User Guide
Save and load bias point
375
Load bias point
Load bias point is a simulation control function that
allows you to set the bias point as an initial condition. A
common reason for giving PSpice initial conditions is to
select one out of two or more stable operating points (set
or reset for a flip-flop, for example).
To use load bias point
1 Run a simulation using the Save Bias Point option in
the Simulation Settings dialog box.
2 Before running another simulation, click the Analysis
tab in the Simulation Settings dialog box.
3 Under Options, select Load Bias Point.
4 Specify a bias point file to load. Include the path if the
file is not located in your working directory, or use the
Browse button to find the file.
5 Click OK.
See Setting up analyses
on
page 7-197
for a description of the
Analysis Setup dialog box.
Pspug.book Page 375 Wednesday, November 11, 1998 1:14 PM