User Guide

Chapter 14 Other output options
370
5 If you selected the AC analysis type, enable an output
format:
a Click the property name for one of the following
output formats: MAG (magnitude), PHASE,
REAL, IMAG (imaginary), or DB.
b Type any non-blank value such as Y, YES or 1.
c Repeat the previous steps (a
) and (b) for as many
AC output formats as you want to see plotted.
6 Repeat steps 2
through 5 for any additional analysis
types you want plotted.
Note
If you do not enable an analysis type, PSpice reports the transient
results.
Generating tables of voltage and current values
You can generate tables of voltage and current values on
nets for any DC sweep, AC sweep, or transient analysis.
To generate tables of voltage or current to the output file
1 Place and connect any of the following parts (from the
PSpice library SPECIAL.OLB).
2 Double-click the part instance to display the Parts
spreadsheet.
Table 15
Use this part... To tabulate this...
VPRINT1 Voltage on the net that the part
terminal is connected to.
VPRINT2 Voltage differential between the two
nets that the part terminals are
connected to.
IPRINT Current through a cut in the net.
(Insert this part in series, like a current
meter.)
I
f
you
d
o not ena
bl
e a
f
ormat, PSpice
defaults to MAG.
Pspug.book Page 370 Wednesday, November 11, 1998 1:14 PM