User Guide

User interface features for waveform analysis
353
The mouse buttons are also used to associate each cursor
with a different trace by clicking appropriately on either
the analog trace symbol in the legend. These are outlined
in the pattern corresponding to the associated cursor’s
crosshair pattern. Given the example in Figure 97,
right-clicking the V(2) symbol will associate cursor 2 with
the V(2) waveform. The analog legend now appears as
shown below.
The Probe Cursor window also updates the A2
coordinates to reflect the X and Y values corresponding to
the V(2) waveform.
cursor 1
cursor 2
Pspug.book Page 353 Wednesday, November 11, 1998 1:14 PM