User Guide

Transient (time) response
263
b Create or change the part definition, making sure
to define the following properties:
Transient (time) response
The Transient response analysis causes the response of the
circuit to be calculated from TIME = 0 to a specified time.
A transient analysis specification is shown for the circuit
EXAMPLE.OPJ in Figure 63. (EXAMPLE.OPJ is shown in
Figure 64.)
The analysis is to span the time interval from 0 to 1000
nanoseconds and values should be reported to the
simulation output file every 20 nanoseconds.
Implementation stimulus name as defined in
the Stimulus Editor
See Chapter 5, Creating parts for
models, for a description of how to create
and edit parts.
Figure 63
Transient analysis setup for EXAMPLE.OPJ.
Pspug.book Page 263 Wednesday, November 11, 1998 1:14 PM