User Guide
Chapter 9 AC analyses
234
3 Click in the cell under the appropriate property
column to edit its value. Depending on the source
symbol that you placed, define the AC specification as
follows:
Table 4
For VAC or IAC
Set this property... To this value...
ACMAG AC magnitude in volts (for VAC) or
amps (for IAC); units are optional.
ACPHASE Optional AC phase in degrees.
Table 5
For VSRC or ISRC
Set this property... To this value...
AC
Magnitude_value [phase_value]
where
magnitude_value
is in volts or
amps (units are optional) and the
optional
phase_value
is in degrees.
I
f
you are a
l
so p
l
anning to run a transient
analysis, see Using VSRC or ISRC
parts on page 3-78 to find out how to
specify the TRAN property.
Pspug.book Page 234 Wednesday, November 11, 1998 1:14 PM