User Guide
Chapter 8 DC analyses
224
When the Bias Point analysis is enabled, the following
information is reported to the output file:
• a list of all analog node voltages
• the currents of all voltage sources and their total
power
• a list of the small-signal parameters for all devices
If Bias Point is enabled, you can suppress the reporting of
the bias point analog node values, as follows:
1 Under the Options tab in the Simulation Settings
dialog box, select Output file in the Category box.
2 Uncheck the box for Bias point node voltages
(NOBIAS).
Pspug.book Page 224 Wednesday, November 11, 1998 1:14 PM