User's Manual

Orbit Irrigation Products
Date:
3/12/20202014/6/
2
General Specification GS-8396
Rev: 0
Page 5 of 8 Copyright ORBIT All Rights Reserved
Figure 1 - Battery Tray Design Guideline
4.1.3 PCB conformal coating with UV tracers required
4.1.4 Output Driving Solenoid Pulse
4.1.4.1 Operating Voltage: 19.9 V
4.1.4.2 Pulse Duration: 12mS minimum
4.1.4.3 Behavior: A reinforcement pulse is required when turning the valve
off
4.2 General Firmware Requirements
4.2.1 Fast Clock Mode – Device must be able to operate in “fast mode” to allow for
accelerated testing (real-time 1min = 1 hour)
4.2.2 Fast clock mode must be initiated using a button configuration (non-
compromising of IP rating)
4.2.3 Firmware version will be displayed on powerup during fast clock mode. It will
remain visible for 2 seconds.
5 MECHANICAL
5.1 General Workmanship Standard
5.1.1 All units being tested must meet requirements per section 6.4 of QA-60
5.2 Threads
5.2.1 All GHT and BSP threads must meet standard (tested with appropriate go
and nogo thread gauge)
5.2.2 Threaded inlet connection will be a brass swivel with TPR overmold
5.3 Environmental Requirements
5.3.1 Maximum operating humidity: 90% RH at 100°F for 24 hours
5.3.2 Operating Temperature: 0°C to 70°C (32°F to 158°F)
5.3.3 Storage temperature: -20°C to 80°C (-4°F to 176°F)