Figure 1 - Battery Tray Design Guideline
4.1.3 PCB conformal coating with UV tracers required
4.1.4 Output Driving Solenoid Pulse
4.1.4.1 Operating Voltage: 19.9 V
4.1.4.2 Pulse Duration: 12mS minimum
4.1.4.3 Behavior: A reinforcement pulse is required when turning the valve
off
4.2 General Firmware Requirements
4.2.1 Fast Clock Mode Device must be able to operate in “fast mode” to allow for
accelerated testing (real-time 1min = 1 hour)
4.2.2 Fast clock mode must be initiated using a button configuration (non-
compromising of IP rating)
4.2.3 Firmware version will be displayed on powerup during fast clock mode. It will
remain visible for 2 seconds.
5 MECHANICAL
5.1 General Workmanship Standard
5.1.1 All units being tested must meet requirements per section 6.4 of QA-60
5.2 Threads
5.2.1 All GHT and BSP threads must meet standard (tested with appropriate go
and nogo thread gauge)
5.2.2 Threaded inlet connection will be a brass swivel with TPR overmold
5.3 Environmental Requirements
5.3.1 Maximum operating humidity: 90% RH at 100°F for 24 hours
5.3.2 Operating Temperature: 0°C to 70°C (32°F to 158°F)
5.3.3 Storage temperature: -20°C to 80°C (-4°F to 176°F)