TDualScan CR-M
I CR-M CR-M is a portable, mini-compact range suited to antenna measurement applications where space is limited or the flexibility of a portable system is required. The system is particularly well-suited for high frequency antenna and production testing.
I CR-M System overview VNA PIN Switch (optional) 959 Spectrum or MiDAS Workstation OFR 9800 Switch Controller (optional) PIN switch (optional) AL-4160 Series Positioner Controller The basic configuration allows for full 3-D patterns to be collected using standard Vector Network Analyzers. The chamber provides a modest level of shielding and easy access to the DUT positioner and compact range feed area.
I CR-M Standard system components Absorbers and anechoic chambers • Size based on selected quiet zone size • Moderate shielding AEMI absorber catalog Reflector system • Rolled edge reflector configuration • Corner-fed geometry • Single-piece reflector Positioning subsystem Positioner controller controls up to 4 axes • Standard AL-160-1 AZ positioner • AL-4160 series positioner controller • AL-060-1P or AL-160-1P Roll axis model tower with squint axis (± 10 deg) and manual slide ORBIT/FR positi
I CR-M System Specifications SYSTEMS CR-M12 CR-M16 CR-M20 Reflector Subsystem Reflector Model AL-23101 AL-23101-16 Al-23101-20 Geometry Corner Fed Corner Fed Corner Fed Frequency Range 8 to 110 GHz(1) 6 to 110 GHz 4 to 110 GHz Quiet Zone Shape Circular Cylinder Circular Cylinder Circular Cylinder Quiet Zone Dimensions (Ø x depth) 12 x 12 in 30 x 30 cm 16 x 16 in 40 x 40 cm 20 x 20 in 50 x 50 cm Cross Polarization (typ) 30 dB 30 dB 30 dB Amplitude Total Variation
I CR-M Typical field probing performance 0,5 5,0 0,3 4,0 0,1 3,0 -0,1 2,0 Phase (deg) Amplitude (dB) Scan Direction: hor., CR-Feed: ver., Freq: 26.5 to 40.