Instruction Manual

110
ORDERING INFORMATION
Refer to Linear Floor Sides - Heavy Duty
Series Specifi cation Table
Ordering Example: AL-4930-1-15
(Where 15 is the desired travel in ft)
Specifi cations - AL-4900 Series Linear Floor Slides, Heavy Duty
Parameter Units
Positioner Model
AL-4909-1-X
Manual
AL-4910-1-X
Motorized
AL-4930-1-X
Motorized
AL-4950-1-X
Motorized
AL-4960-1-X
Motorized
Operational
Travel
(1)
ft 6.5 to 50
m 2 to 15
Vertical Load
lbs 4,400 4,400 11,000 25,000 110,000
kg 2,000 2,000 5,000 11,300 50,000
Fore-Aft Bending Moment
ft-lbs 14,685 14,685 29,500 49,000 100,000
kg-m 2,030 2,030 4,100 6,800 13,830
Side Bending Moment
ft-lbs 14,685 14,685 29,500 49,000 100,000
kg-m 2,030 2,030 4,100 6,800 13,830
Motor Drive Power
hp - 1/8 1/8 1/8 1/8
Nominal Speed
in/sec - 4.9 2 2 2
m/sec - 125 50 50 50
Standard Angle Transducer Format
--
Dual Speed
Synchro
Dual Speed
Synchro
Dual Speed
Synchro
Dual Speed
Synchro
Data Take-Off Accuracy (RMS)
in - 0.02 0.02 0.02 0.02
mm - 0.5 0.5 0.5 0.5
Repeatability
in - 0.005 0.005 0.005 0.005
mm - 0.13 0.13 0.13 0.13
Physical
Weight (approx.)
lbs 132 + 187.5/ft 200 + 187.5/ft 334/ft 501/ft 668/ft
kg 60 + 280/m 90 + 280/m 500/m 750/m 1000/m
Width
in 27.6 27.6 47.2 59.1 59.1
mm 700 700 1,200 1,500 1,500
Height
in 9.6 9.6 11.0 12.0 21.7
mm 245 245 280 305 550
Options
EN001
Incremental Encoder
Accuracy (RMS)
in - 0.02 0.02 0.02 0.02
mm - 0.5 0.5 0.5 0.5
EN004
Absolute Encoder Accuracy
(RMS)
in - 0.02 0.02 0.02 0.02
mm - 0.5 0.5 0.5 0.5
(1)
For other linear travel ranges consult ORBIT/FR