INFORMATION REQUIREMENTS FOR LOCAL SPACE HEATERS (EU)2015/1188
Item
Model
identifier
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage
local space heaters only (select one)
Nominal heat output
RRE 510 A
P
nom
0.5
kW
manual heat charge control, with
integrated thermostat
N/A
RRE 810 A
P
nom
0.8
kW
manual heat charge control with
room and/or outdoor
temperature feedback
N/A
RRE 1010 A
P
nom
1.0
kW
electronic heat charge control
with room and/or outdoor
temperature feedback
N/A
RRE 1310 A
P
nom
1.3
kW
fan assisted heat output
N/A
RRE 1510 A
P
nom
1.5
kW
Type of heat output/room temperature
control (select one)
RRE 1810 A
P
nom
1.8
kW
single stage heat output and no
room temperature control
No
Minimum heat output
(indicative)
RRE 510 A
P
nom
0.5
kW
Two or more manual stages, no
room temperature control
No
RRE 810 A
P
nom
0.8
kW
with mechanic thermostat room
temperature control
No
RRE 1010 A
P
nom
1.0
kW
with electronic room temperature
control
No
RRE 1310 A
P
nom
1.3
kW
electronic room temperature
control plus day timer
No
RRE 1510 A
P
nom
1.5
kW
electronic room temperature
control plus week timer
Yes
RRE 1810 A
P
nom
1.8
kW
Other control options (multiple
selections possible)
Maximum continuous
heat output
RRE 510 A
P
nom
0.5
kW
room temperature control, with
presence detection
No
RRE 810 A
P
nom
0.8
kW
room temperature control, with
open window detection
Yes
RRE 1010 A
P
nom
1.0
kW
with distance control option
Yes
RRE 1310 A
P
nom
1.3
kW
with adaptive start control
No
RRE 1510 A
P
nom
1.5
kW
with working time limitation
No
RRE 1810 A
P
nom
1.8
kW
with black bulb sensor
No
Auxiliary electricity consumption
At nominal heat output
All models
el
max
0,000
kW
At minimum heat output
All models
el
min
0,000
kW
In standby mode
All models
el
SB
0,0008
kW
Contact details info