User Manual
Buzzer – – beeps 3 times on power ON after detecting PPM on the PPM input (AETR/TAER)
LED – DSM2, 1024 mode – OFF
DSM2, 2048 mode – single blinks
DSMx, 22ms mode – double blinks
DSMx, 11ms mode – triple blinks
Functionality:
Power ON:
When powered up the module is waiting for valid PPM signal to be detected.
As soon as PPM signal is detected the buzzer generates three short beeps (0.1s) indicating that the system is ready.
When module starts transmitting RF packets red LED is will blink according to the mode selected during binding (!).
For example if your receiver supports only DSM2, 2048ms and it is bound to the Tx module in this mode, Tx module will
produce single blinks during the normal operation.
Modes indicated by the LED in Spektrum Auto mode:
DSM2, 1024 mode – OFF
DSM2, 2048 mode – single blinks
DSMx, 22ms mode – double blinks
DSMx, 11ms mode – triple blinks
Binding procedure:
After power ON with the Button2 detected pressed and valid PPM signal present the module generates three sort beeps and
enters binding procedure.
The module sets output power at 0.006mW and starts binding procedure. Based on your receiver capability one of
following modes will be selected:
DSM2, 1024 mode
DSM2, 2048 mode
DSMx, 22ms mode
DSMx, 11ms mode
After that the module generates three short beeps. If the bind was unsuccessful it generates one long beep. After binding
procedure is over the module enters the regular transmitting mode and stays in this mode until power turned off.
The settings for transmission will not be changed if the binding procedure was unsuccessful. If the binding procedure was
successful the settings will be changed to the new ones.
If the receiver and the module can operate with different protocols following priority is taken (from most simple to most
advanced):
DSM2->DSMx
1024->2048
22ms->11ms
ID change:
When powered up with Button1 pressed the new ID will be generated. The procedure of new ID generation is initiated
regardless if PPM signal present or not. After detection of Button 1 pressed module waits for 3 sec then generated a new ID
and buzzer generates long beep(0.3 sec). After this the module waits until the button 1 is released. When button is released
the module detects PPM signal from the radio. In Spektrum mode following binding procedure is necessary.
3. Spektrum Manual mode SW1-OFF, SW3-ON
Switches, LED and Buzzer:
SW2 provides channel mapping according to switch description (AETR/TAER)
SW4: DSM2/DSMx. Selects DSM2/DSMx protocols in manual mode
OFF-DSM2
ON-DSMx
SW5: 11ms/22ms for DSM2 and DSMx
ON-11ms
OFF-22ms
SW6: 1024/2048 for DSM2 only.
OFF-1024
ON-2048
SW7, SW8 change output power selection according to switches description (see Table 1)
Button1 – ID change
Button2 – When pressed during operation the output power is reduced to 1mW for a range check. When pressed during
power on a binding procedure will be initiated
Buzzer – beeps 3 times on power ON after detecting PPM on the PPM input (AETR/TAER)
LED – blinks accordingly to the mode selected by switches.
Functionality:
Power ON:
When powered up the module is waiting for valid PPM signal to be detected.
As soon as PPM signal is detected the buzzer generates three short beeps(0.1s) indicating that the system is ready.
When module transmits RF packets red LED blinks in accordance to the mode selected by switches.
DSM2, 1024 mode – OFF
DSM2, 2048 mode – single blinks
DSMx, 22ms mode – double blinks
DSMx, 11ms mode – triple blinks
Binding procedure:
After power ON with the Button2 pressed and valid PPM signal present the module generates three sort beeps and enters
binding procedure. The module sets output power at 0.006mW and initiated binding procedure. During binding the module
uses transmission settings selected by switches. After that the module generates three short beeps if the bind was