User's Manual
Configuring Oracle Database and Oracle Net Services for Oracle DCE Integration
10-18 Oracle Database Advanced Security Administrator's Guide
greater than the server DCE_PROTECTION level. If this entry is not specified,
cell-wide default protection is used. The options follow:
DCE.TNS_ADDRESS_OID
DCE.TNS_ADDRESS_OID is an optional parameter that enables you to specify an
alternative to the default value as follows:
DCE.TNS_ADDRESS_OID=1.3.22.1.x.x
DCE.LOCAL_CELL_USERNAMES
DCE.LOCAL_CELL_USERNAMES is an optional parameter that defines the format
used to specify the principal name (username), with or without the cell name. The
choice you make for this parameter should be determined by whether or not users
are making connections across cells—with unique names. The default for
DCE.LOCAL_CELL_USERNAMES is now TRUE (it was set to FALSE in the DCE
Integration 2.1.6 release).
The associated options follow:
Option Description
NONE Perform no protection for the current connection
DEFAULT Use the default cell-wide protection level
CONNECT Perform protection only when the client establishes a
relationship with the server
CALL Perform protection only at the beginning of each remote
procedure call when the server receives the request
PKT Ensure that all data received is from the expected client
PKT_INTEG Ensure and verify that none of the data transferred between the
client and server has been modified
PRIVACY Perform protection as specified by all of the previous levels and
also encrypt each RPC argument value and all user data in each
call
See Also: "Step 2: Modify the CDS Attributes File and Restart the
CDS" on page 10-20.