Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide For HBA Models SG-XPCIE2FC-ATCA-Z, SG-PCIE2FC-ATCA-Z, SG-XPCIE2FC-ATCA-N, and SG-PCIE2FC-ATCA-N Part No.
Copyright © 2008, 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means.
Contents Preface 1. v HBA Overview Kit Contents 1 1 HBA Features and Specifications 1 Operating System Requirements 3 System Interoperability 3 Host Platform Support 4 Storage System Support 4 Fibre Channel Switch Support Software Support 2.
Removing the Hardware 3. 15 ▼ To Prepare the HBA for Hot-Plug Removal Using the Module Handle ▼ To Prepare the HBA for Hot-Plug Removal (Solaris OS) ▼ To Remove the HBA Hardware HBA Software Installation 16 17 Installing Software for the Solaris OS ▼ 17 To Install or Update the Driver From a Patch Solaris Diagnostic Support 17 18 Installing Software for the Wind River Linux OS ▼ 18 To Obtain the Wind River Development Kit 18 Installing Software for the Red Hat Enterprise Linux OS ▼ 4.
Preface This installation guide describes how to install and remove Oracle’s Sun StorageTek ATCA 4Gb FC dual port host bus adapter (HBA). It also explains how to verify the driver version and install any necessary patches. This document is written for technicians, system administrators, application service providers (ASPs), and users who have advanced experience troubleshooting and replacing hardware.
Accessing Related Documentation The document listed in this section is available at: http://docs.sun.com/source/819-0139/ Title Part Number Solaris Fibre Channel and Storage Multipathing Administration Guide 819-0139 Documentation, Support, and Training Sun Function URL Documentation http://docs.sun.com Support http://www.sun.com/support/ Training http://www.sun.com/training/ Note – Prior to contacting Oracle support, record the HBA serial number in a safe location.
CHAPTER 1 HBA Overview This chapter provides a basic overview of Oracle’s Sun StorageTek ATCA 4Gb FC Dual Port host bus adapter (HBA), which uses Emulex technology. This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the HBA.
TABLE 1-1 2 HBA Features and Specifications Feature Description AMC connector B+ PCI signaling environment PCI Express x4 (4 active lanes) PCI transfer rate (maximum) PCI Express Generation One (2.
Operating System Requirements The HBA requires the operating system (OS) levels, at minimum, listed in TABLE 1-2.
Host Platform Support The HBA is supported by the platforms and operating systems (OSs) listed in TABLE 1-3. TABLE 1-3 Platform and Operating System Support Platform Supported OS Netra™ ACTA 3060 and 3220 servers Solaris, Linux* * See TABLE 1-2 for specific OS versions. The system must have an available AdvancedMC slot in which you can install the HBA.
■ 10 Gb Brocade M6140 Director ■ 10 Gb Brocade Mi10K Director ■ 2 Gb McDATA Sphereon 4300 switch ■ 2 Gb McDATA Sphereon 4500 switch ■ 2 Gb McDATA Intrepid 6064 Director ■ 4 Gb McDATA Sphereon 4400 and 4700 switches ■ Cisco MDS 9120 Fabric switch ■ Cisco MDS 9124 24-Port Multilayer Fabric switch ■ Cisco MDS 9140 Fabric switch ■ Cisco MDS 9216A Multilayer Fabric switch ■ Cisco MDS 9216i Multilayer Fabric switch ■ Cisco MDS 9509 Multilayer Director ■ Cisco MDS 9513 Multilayer Director
6 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
CHAPTER 2 Hardware Installation and Removal This chapter describes the tasks required to install and remove the HBA. Refer to your system installation or service manual for detailed instructions.
■ Place the HBA on a properly grounded antistatic work surface pad when it is out of its protective antistatic bag. Installing the Hardware The hardware installation process involves the following general steps: ■ “To Verify the PPS Shelf Manager Firmware Version” on page 8 ■ “To Install the HBA” on page 8 ■ “To Connect the Optical Cable” on page 10 The following sections describe these steps in more detail.
FIGURE 2-1 Removing the AMC Slot Filler Panel Note – A module handle is at the bottom of the HBA. When you install the HBA, the position of the module handle (pulled out or pushed in) does not matter. 3. Insert the HBA through the cutout and into the AMC slot (FIGURE 2-2).
FIGURE 2-2 Inserting the HBA Into the AMC Connector 4. Carefully plug the HBA into the AMC connector (FIGURE 2-2). Ensure that the HBA is seated correctly in the connector. Caution – Do not use excessive force when installing the HBA into the slot. You might damage the AMC connector on the Netra board, causing permanent damage to the HBA or board. If the HBA does not seat properly when you apply even pressure, remove the HBA and carefully reinstall it. 5.
TABLE 2-1 Optical Cable Specifications Fiber-Optic Cable Maximum Length Minimum Length Connector 62.5/125 µm (multimode) 300 meters at 1.0625 Gbps 150 meters at 2.125 Gbps 70 meters at 4.25 Gbps 2 meters LC 50/125 µm (multimode) 500 meters at 1.0625 Gbps 300 meters at 2.125 Gbps 150 meters at 4.25 Gbps 2 meters LC Follow these steps when connecting the optical cable: 1. Connect the fiber-optic cable to an LC connector on the HBA as shown in FIGURE 2-3.
3. Observe the port LEDs status for the power-on self test (POST) results as shown in TABLE 2-2. TABLE 2-2 summarizes port LED indicator combinations. Refer to FIGURE 2-4 to determine the location of the LEDs. Each port has a corresponding set of LEDs that provide a visual indication of the operating state.
FIGURE 2-4 LEDs ▼ To Verify the Installation (Solaris OS) 1. Use the cfgadm command to verify proper HBA installation. % cfgadm Ap_Id c3 c4 pcie5 Type fc fc fibre/hp Receptacle connected connected connected Occupant configured configured configured Condition ok ok ok If the HBA is properly installed and connected, you will see output similar to that shown in the example. 2. If an HBA adapter is shown as unconfigured or disconnected, use the cfgadm -c configure command to configure the adapter.
▼ To Verify Attached Storage (Solaris OS) 1. Use the cfgadm -al command to verify attached storage. % cfgadm -al Ap_Id Type c3 fc-fabric c3::200600a0b816005e disk c3::200700a0b816005e disk c4 fc pcie5 fibre/hp Receptacle Occupant Condition connected configured unknown connected configured unknown connected configured unknown connected unconfigured unknown connected configured ok If the HBA is properly installed and storage is connected properly, you will see output similar to that shown in the example.
Removing the Hardware The following instructions describe the tasks required to remove the HBA. Refer to your system installation or service manual for detailed HBA adapter removal instructions. The hardware removal process involves following these general steps: 1. Preparing the HBA for hot-plug removal with one of the following: ■ The module handle ■ The Solaris OS 2.
3. Use the cfgadm -c disconnect command to prepare the HBA for removal. A flashing Power indicator LED indicates that the HBA is being prepared for removal. A dark Power indicator LED indicates that the HBA is ready to be removed. ▼ To Remove the HBA Hardware 1. After the HS LED stops blinking and stays blue, pull the module lever out the rest of the way, and pull the HBA from the slot.
CHAPTER 3 HBA Software Installation This chapter describes the Solaris driver software that is required to support the HBA. The chapter contains the following section: ■ “Installing Software for the Solaris OS” on page 17 ■ “Installing Software for the Wind River Linux OS” on page 18 ■ “Installing Software for the Red Hat Enterprise Linux OS” on page 19 Installing Software for the Solaris OS The HBA driver is included in the Solaris 10 6/06 (s10u2) release, at minimum.
Solaris Diagnostic Support Diagnostic support for the HBA is included in Oracle’s SunVTS software beginning with version 6.3. SunVTS is included with the Solaris 10 11/06 (s10u3) release and is also available for download at: http://www.sun.
Note – When you contact Wind River customer support, be sure to specify all components in your hardware environment (including this HBA). This will ensure you receive all software that is required to run in the hardware environment. Installing Software for the Red Hat Enterprise Linux OS No updates are required to support the HBA on minimum supported versions of the Red Hat Enterprise Linux OS. For diagnostic support, you might need to rebuild the Linux driver.
20 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
CHAPTER 4 Known Issues This chapter contains any known issues with the HBA. The chapter contains the following topic: ■ “Potential AMC I/O Card Corruption” on page 21 Potential AMC I/O Card Corruption Issue: If you are using Oracle’s Sun Netra CT900 ATCA Blade Server or are using any Pigeon Point Systems Shelf Manager, the Shelf Manager will corrupt any AMC I/O cards when the Shelf Manager firmware is not at the latest version.
● If you have a non-Oracle ATCA chassis, contact Pigeon Point Systems customer support for information about downloading the latest firmware version: http://www.pigeonpoint.com/contact.html You can also contact Pigeon Point Systems customer support at: support@pigeonpoint.
APPENDIX A Declaration of Conformity, Safety, and Regulatory Statements This appendix provides Declaration of Conformity, safety, and regulatory statements for the HBA.
24 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
Declaration of Conformity To receive a copy of the latest Declaration of Conformity (DoC) for the product, either contact your local Oracle sales representative, or create an online request at: https://www2.sun.de/dct/forms/reg_us_1607_755_0.
26 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
Safety Agency Compliance Statements Read this section before beginning any procedure. The following text provides safety precautions to follow when installing an Oracle product. Depending on the type of power switch your device has, one of the following symbols may be used: On – Applies AC power to the system. Off – Removes AC power from the system.
Caution – Not all power cords have the same current ratings. Do not use the power cord provided with your equipment for any other products or use. Household extension cords do not have overload protection and are not meant for use with computer systems. Do not use household extension cords with your Sun product. The following caution applies only to devices with a Standby power switch: Caution – The power switch of this product functions as a standby type device only.
Energy Storage Module Caution Caution – There is a danger of shock or equipment damage if energy storage modules are mishandled or incorrectly replaced. When replacing the energy storage modules, use only replacement modules that have been provided by Sun Microsystems, following the instructions provided in the product service manual. Do not disassemble modules or attempt to recharge them outside of the system.
Laser Compliance Notice Sun products that use laser technology comply with Class 1 laser requirements. ■ Ce produit est destiné à être utilisé dans des zones à accès limité, dans lesquelles les accès sont contrôlés au moyen de systèmes de sécurité (par exemple, à clé, verrou, dispositif ou badge). Le personnel autorisé à accéder à ces zones doit avoir été préalablement informé des raisons justifiant la limitation des accès et de toutes les précautions à prendre.
Positionnement d’un produit Sun Attention – Evitez d'obstruer ou de recouvrir les orifices de votre produit Sun. N'installez jamais un produit Sun près d'un radiateur ou d'une source de chaleur. Si vous ne respectez pas ces consignes, votre produit Sun risque de surchauffer et son fonctionnement en sera altéré. Conformité SELV Le niveau de sécurité des connexions E/S est conforme aux normes SELV. système.
endommager ou de vous exposer à un choc électrique. Remplacez les modules de stockage d’énergie uniquement par les modules de remplacement que Sun Microsystems fournit, en veillant à respecter les instructions indiquées dans le manuel d’entretien du produit. Ne démontez pas les modules. N’essayez pas de les recharger hors du système. Ne jetez pas les modules, mais retournez-les à Sun Microsystems conformément aux procédures Sun relatives au produit.
Attention – Afin d'empêcher des températures de fonctionnement extrêmes provoquées par une aération insuffisante, assurez-vous de fournir une aération appropriée pour un fonctionnement du matériel en toute sécurité Avis de conformité des appareils laser Les produits Sun qui font appel aux technologies lasers sont conformes aux normes de la classe 1 en la matière. ■ Stellen Sie sicher, dass Spannung und Frequenz der Stromversorgung den Nennleistungen auf dem am Gerät angebrachten Etikett entsprechen.
Modifikationen des Geräts Nehmen Sie keine elektrischen oder mechanischen Gerätemodifikationen vor. Sun Microsystems ist für die Einhaltung der Sicherheitsvorschriften von modifizierten Sun-Produkten nicht haftbar. Aufstellung von Sun-Geräten Achtung – Geräteöffnungen Ihres SunProdukts dürfen nicht blockiert oder abgedeckt werden. Sun-Geräte sollten niemals in der Nähe von Heizkörpern oder Heißluftklappen aufgestellt werden.
Sicherheitshinweise zum Energiespeichermodul Achtung – Bei unsachgemäßer Handhabung oder unsachgemäßem Austausch von Energiespeichermodulen besteht die Gefahr eines Stromschlags oder Geräteschadens. Verwenden Sie beim Austausch von Energiespeichermodulen nur Ersatzmodule, die von Sun Microsystems bereitgestellt wurden, und folgen Sie den im Service Manual zum Produkt enthaltenen Anweisungen. Versuchen Sie auf keinen Fall, Module auszubauen oder diese außerhalb des Systems wiederaufzuladen.
Warnungen bezüglich in Racks eingebauter Systeme Die folgenden Warnungen gelten für Racks und in Racks eingebaute Systeme: Achtung – Aus Sicherheitsgründen sollten sämtliche Geräte von unten nach oben in Racks eingebaut werden. Installieren Sie also zuerst die Geräte, die an der untersten Position im Rack eingebaut werden, gefolgt von den Systemen, die an nächsthöherer Stelle eingebaut werden, usw. Achtung – Verwenden Sie beim Einbau den Kippschutz am Rack, um ein Umkippen zu vermeiden.
Precaución – Superficie caliente. Evite todo contacto. Las superficies están calientes y pueden causar lesiones personales si se tocan. Precaución – Voltaje peligroso. Para reducir el riesgo de descargas eléctricas y lesiones personales, siga las instrucciones. En función del tipo de interruptor de alimentación del que disponga el dispositivo, se utilizará uno de los símbolos siguientes: Encendido – Suministra alimentación de CA al sistema. Apagado – Corta la alimentación de CA del sistema.
servicio del producto. No desmonte módulos ni intente recargarlos fuera del sistema. No elimine los módulos. En su lugar, devuélvalos a Sun Microsystems de conformidad con los procedimientos de Sun para el producto. Precaución – En los productos que cuentan con varios cables de alimentación, debe desconectar todos los cables de alimentación para cortar por completo la alimentación eléctrica del sistema.
Precaución – Los equipos instalados por deslizamiento o sobre raíles no deben utilizarse como estantería o espacio de trabajo. Advertencia sobre el sistema en bastidor Las advertencias siguientes se aplican a los sistemas montados en bastidor y a los propios bastidores. la utilización de láser Los productos Sun que utilizan tecnología láser cumplen los requisitos establecidos para los productos láser de clase 1.
Danmark Advarsel! – Litiumbatteri — Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren. Norge Advarsel – Apparatet må tilkoples jordet stikkontakt. Sverige Varning – Apparaten skall anslutas till jordat uttag. Suomi Varoitus – Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin.
Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Bureau of Standards Metrology and Inspection (BSMI) — Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product. FCC Class A Notice This device complies with Part 15 of the FCC Rules.
BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label.