6
Attention
If the chimney pressure is too low or too high this may cause problems with the working of
the stove.
Outdoor air supply
If the deviation from the required pressure (section 4) is over 25%, suitable changes to the
chimney should be made.
3.2. Safety rules
During stove installation, you must comply with the safety rules.
The appliance shall be installed on floors with an adequate load-bearing capacity. If an
existing construction doesn't meet these prerequisite, suitable measures (e.g. load
distributing plate) shall be taken to achieve it.
Pay attention to minimum distance required from the wall, combustible materials and to
protection of the floor
3.3 Minimum distances to combustibles
A
800mm
In the area of thermal
radiation
B
150mm
Back space between the wall
and stove
C
150mm
Side space between wall and
stove