3. Installation of the Stove and the flue pipe connection
3.1. Flue pipe connection
All flue pipe that is used to connect the stove to the chimney must comply with national
regulations. All connections from the stove into the chimney must be firm and tightly
connected.
Be careful that flue pipe does not enter into the free section of the chimney.
Maintain the correct distances specified by building regulations between the flue pipe and
combustible material.
When the stove has a rear flue connection, the Tee cap should be securely attached.
This appliance must never be connected to a shared flue system.
Attention
If the chimney pressure is too low or too high this may cause problems with the working of
the stove.
Outdoor air supply
If the deviation from the required pressure (section 4) is over 25%, suitable changes to the
chimney should be made.
3.2. Safety rules
During stove installation, you must comply with the safety rules.
The appliance shall be installed on floors with an adequate load-bearing capacity. If an
existing construction doesn't meet these prerequisite, suitable measures (e.g. load
distributing plate) shall be taken to achieve it.
Pay attention to minimum distance required from the wall, combustible materials and to
protection of the floor.