Operation Manual

© Calibre UK Limited Issue 2.00 30 March 2012, W: www.calibreuk.com
T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com 21
3.8. PiP
The HQView-500S has a PiP menu. It contains adjustments associated with setting up source, position
and size of a picture in picture video image. HQView-510/520/530 have a Multiple Unit menu instead.
HQView-510/520/530 can be booted as HQView-500S through the menu system though.
3.8.1. PiP Input
Selects the video source for the PiP window. The available PiP video sources depend on the currently
displayed (main) video source. If the main video source is HDMI, DVI, DVI-A, VGA or COMPONENT
the available PiP sources are CVBS1, CVBS2, S-VIDEO and HD-SDI. If the main video source is
CVBS1, CVBS2, S-VIDEO or HD-SDI the available PiP sources are HDMI, DVI, DVI-A, VGA and
COMPONENT.
3.8.2. PiP Mode
Settings: Off, PIP, PAP, POP
Three picture in picture modes can be invoked. PIP displays a second channel within the main image.
PAP displays both pictures side by side scaled to the vertical size of the panel. POP displays both
images side by side preserving the aspect ratio of each source. The unused areas of the panel are
displayed black.
3.8.3. PiP Size
Settings: Small, Medium, Large
Selects the size of the PiP image.
Note: The larger PiP sizes are not available for certain main and PiP source combinations.
3.8.4. PiP Position
Settings: Top Left, Top Right, Bottom Left, Bottom Right, Free H/V
Selects the quadrant where to show the PiP image. When Free H/V is selected the horizontal and
vertical PiP positioning sliders become available and the PiP can be moved over the screen.