User Manual
OPR-3301 SS08xxx
6
6. Optical Specifications
6.1. Laser Scan Specifications
Parameter Specification Unit
Light-emitting element Red laser diode -
Emission wavelength 650±10 nm (25°C) nm
Light output 1.0 mW or less (Class 1) mw
Scanning method Bi-directional scanning -
Scanning speed 100±20 scans/s
Scan angle 54±5 °
Scan angle
Read angle range 44 (Min) °
6.2. Curvature of Scan
Maximum gap between the straight line connecting both ends of the laser scan line and the actual
laser scan line: Less than 1.27° curvature from the scan origin.
Maximum of 3.3 mm curvature when measured at a point 150 mm away from the scan origin. (The
skew angle of this measurement was zero degrees.)
Measurement was done from the center of scan line.
Horizontal Line
C
u
r
v
a
t
u
r
e
T
i
l
t
Figure 3: Laser scan tilt and curvature
7. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each section.
<Conditions>
Ambient temperature and humidity: Room temperature (5 to 35º C)
Room humidity (45% to 85% RH)
Ambient light: 500 to 900 lx
Background of barcode: Barcode = black
Power supply voltage: 5.0 V
Decoding test: Approve the performance when decoding is successful in all ten tests.
(Decoding is deemed successful when completed in 0.5 seconds or less.)
7.1. Laser Scan Specifications
0.45 or higher (over 70% of reflectivity of space and quiet zone).
PCS=
Reflectance of white bar-Reflectance of black bar
Reflectance of white bar
Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window