User's Manual
OPN-3102n
1st
22
SPECIFICATIONS MANUAL
9 Environmental Specifications
9.1 Temperature
Scanning performance is guaranteed when the ambient temp. is within the following range:
Operating Temperature: -10 ~ 50
°C
Storage Temperature: -20 ~ 60
°C
* Please charge when the temperature is between 0 and 40°C. When the temperature is over 40°C,
charging may stop to prevent battery breakdown.
9.2 Humidity
Scanning performance is guaranteed when the ambient humidity within following range:
Operating Humidity: 20 ~ 85%RH (no condensation, no frost)
Storage Humidity: 20 ~ 85%RH (no condensation, no frost)
9.3 Ambient Light Immunity
Scanning performance is guaranteed when the illumination on a barcode surface is between
zero and the following values:
Incandescent light: 10,000 lx
Fluorescent light: 10,000 lx
Sunlight: 100,000 lx
<Conditions>
Barcode: 0.33 mm JAN specified in Chapter 8.1.
Distance: 95 mm from the front edge of the scanner
Angle:
α = 0°, β =+15°, γ = 0°
Curvature: R = ∞
Power-supply voltage: 3.7V
* Avoid direct or specula reflection from the light source as it may blind the scanners optical receiver.
9.4 Dust and Drip Proof
IEC IP54 equivalent
Protection against solid objects: Level 5 equivalent (Dust proof type)
Prevent dust ingress to inside. Even if slight dust intrusion will not inhibit normal operation.
Protection against liquids: Level 4 equivalent (Splash proof type)
Protected against water splash from any direction.
* () is JIS drip-proof type.