User's Manual
OPN-3102n
1st
19
SPECIFICATIONS MANUAL
8.3 Printed Contrast Signal (PCS)
0.2 or higher
<Conditions>
MRD : 10% and higher
(70% or higher reflectivity of space and quiet zone)
Distance : 125mm from the front edge of the scanner
Barcode Sample : UPC specified in Chapter 8. (Resolution: 0.33 mm, PCS: 0.3)
MRD = Minimum reflectance of white bar - Maximum reflectance of black bar
* Be sure to keep the optical window clean without dirt or scratches, or it may have a detrimental effect on
the reading characteristics.
8.4 Minimum Resolution
1D Code : 0.1 mm (3.9 mil) Code 39 specified in Chapter 8.1
GS1-Databar : 0.127 mm (5 mil) GS1 Databar Limited specified in Chapter 8.1
Stacked Code : 0.169 mm (6.7 mil) PDF417, GS1 Databar Limited Composite specified in Chapter 8.1
2D Code : 0.169 mm (6.7 mil) QR Code, Data Matrix specified in Chapter 8.1
<Conditions>
Barcode Sample The above codes specified in Chapter 8.1
Distance 95 mm from the front edge of the scanner
Angle
α = 0°, β =+15°, γ = 0°
Curvature R = ∞
8.5 Barcode Width
Code 39 with width of 100 mm and resolution of 0.2 mm can be read
<Conditions>
Barcode Sample 0.20 mm Code 39 / PCS 0.9 specified in Chapter 8.1
Distance 150 mm from the front edge of the scanner
Angle
α = 0°, β =+15°, γ = 0°
Curvature R = ∞
Figure 7: Wide Barcode
PCS =
Reflectance of white space – Reflectance of black bar
Reflectance of white space