User's Manual
OPN-3002n DOC ID:SS13001
13
β
γ
+
+
+
-
-
-
Figure 7 : Pitch, Skew and Tilt
8.7. Curvature
0.33 mm 12-digit UPC : R ≧ 20 mm
0.15 mm 10-digit Codabar : R ≧ 16 mm
<Conditions>
Bar Code Sample : 0.33 mm UPC, 0.15 mm Codabar specified in Chapter 7.1
Distance : 85 mm from the front edge of the scanner
Angle
: α = 0°, β =+15°, γ = 0°
R
バーコード
Figure 8 : Curvature
Note: Scanning may fail due to the specular reflection of LED illumination when the reflectivity is high.
Barcode