12-5. Product Drop Test (Without Packaging)
No malfunction should occur after the following drop test.
As shown below, drop the data collector from 120cm above the concrete floor. (three times from
each of its 6 sides)
12-6. Collective Package Drop Test
No malfunction should occur after the following drop test.
Drop the collective package box from 70cm above the concrete floor once its one corner, three
edges and six sides.
12-7. Static Electricity
Air discharge: 8kV max (No malfunction)
15kV max (No destruction)
Contact discharge: 4kV max (No malfunction) (Discharge point: Screws which fix cases)
10kV max (No destruction)
Measurement environment: Use electrostatic testing device compliant with IEC61000-4-2
Discharge resistance: 330Ω
Capacitor charging: 150pF
12-8. Reliability
MTBF: 10,000 hours