OPL-2724 SS08057
- -
8
7-5. Tilt Angle
γ = ± 20°
<Conditions>
Barcode Sample: OPTOELECTRONICS test sample
PCS: 0.9
Resolution: 0.26 mm
Symbologies: 13-digit JAN
(96 mm from the optical window of the scanner.)
Figure 6: Tilt angle
7-6. Curvature
With 8-digit JAN barcodes, decoding performance is guaranteed when R15mm.
With 13-digit JAN barcodes, decoding performance is guaranteed when R20mm.
(96 mm from the optical window of the scanner.)
Figure 7: Curvature
<Conditions>
Barcode Sample: OPTOELECTRONICS test sample
PCS: 0.9
Resolution: 0.26 mm