7.4 Operating and Storage Environment
These values should be considered preliminary and are to be investigated later.
7.4.1 Shock
Operating 15 G, 18 ms
Non-operating 30 G, 11 ms
7.4.2 Vibration
Operating Linear: 20-300 Hz, 0.75 G (0 to peak)
Random: 10-300 Hz, 0.004 g
2
/Hz
Non-operating 5-20 Hz, 0.195 inches (double amplitude)
20-500 Hz, 4.0 G (0 to peak) Sweep Rate 0.5 octave/minute minimum
7.4.3 Operating Temperature and Humidity
Temperature -10°C to 55°C (14°F to 131°F)
Humidity 5-95% RH non-condensing
33°C (maximum wet bulb)
Thermal Gradient 20°C/hour (maximum)
Humidity Gradient 20%/hour (maximum)
7.4.4 Non-Operating Temperature and Humidity
Temperature -40°C to 65°C (-40°F to 149°F)
Humidity 5-95% RH non-condensing
35°C (maximum wet bulb)
Thermal Gradient 30°C/hour (maximum)
Humidity Gradient 20%/hour (maximum)
7.4.5 Altitude
Operating -1000 feet to 10,000 feet (-305M to 3,050M)
Non-Operating -1000 feet to 40,000 feet (-305M to 12,200M)