3.3.4.2 Maximum Trace Length
The maximum trace length depends on the trace capacitance, but on average it is advisable to
limit the length to a maximum of 200mm.
The module controls the signals RST and CLK. A totem-pole output drives these signals high
or low. The signal I/O is a bi-directional data line. The I/O interface is shown in Figure 10.
The module and the (U)SIM (in the SIM card holder), located on both ends of the lines,
control this data line. Either the module or the (U)SIM can pull this line low, through an
open-collector. The line is pulled-up by a resistor of 12k.
Figure 10: I/O interface
During certification of the module the SIM interface is tested. A SIM card is simulated by the
test equipment. The test conditions are shown in Table 15 and Table 16. The test equipment
loads the I/O line with 30pF.
Contacts Low level High level Max. capacitive load
C1 (Vcc) --- I = 6 mA
C2 (RST)
I = -200 µA I = +200 µA
30 pF
C3 (CLK)
I = -20 µA I = +20 µA
30 pF
C5 (GND) --- ---
C6 ((Vpp) --- ---
C7 (I/O)
ME input
ME output
V = 0 V
I = -1 mA
I = +20 µA
I = +20 µA
30 pF
Table 15: Nominal test conditions on 3V SIM/ME interface
Module SIM card