2.2GHz. Additionally, this filter includes an ESD protection circuitry which prevents the
protected device from destruction when subjected to ESD surges up to 8kV (Contact) and
15kV (Air).
· Figure 7: Schematic of EMIF03-SIM01
Figure 8: Insertion Loss Characteristic
3.3.3 Electrical specifications of the UICC – Terminal interface
This section is an excerpt from the standards, but it is very important that the integrator takes
care in the design phase to comply to these specifications, since they are essential to the final
certification of the integrated module (also see chapter 8 on certification).