Scanner User Manual
Table Of Contents
- April 2002
- Part I
- General Information
- Unpacking
- Factory Technical Support
- Part II Installation and SetUp
- A.\) Installation – Keyboard Wedge Interface
- Reset All Defaults – Keyboad Wedge Interface
- Computer Type Selection (for Keyboard Wedge only)
- Intercharacter Delay for Keyboard Wedge interface
- B.\) Installation – RS232 Interface
- Reset All Defaults – RS232
- RS-232C Communication Parameters
- Handshaking Protocol
- Baud Rate
- Data Bits / Stop Bits / Parity
- C.\) Installation – USB Interface
- Reset All Defaults - USB Interface
- Part IIIBar Code Menu Functions
- Section A Programming the Scanner
- Symbology Selection
- Symbology Additions
- Setting the Number of Characters to be Scanned
- UPC Settings
- EAN-13 and EAN-8 Settings
- Code 39 Settings
- Codabar Settings
- MSI/Plessey Settings
- Code 128, EAN 128 Settings
- IATA Settings
- Telepen Settings
- Case Conversion
- Setting a Prefix or Suffix
- Prefix Settings
- Suffix Settings
- Direct Input Keyboard Keys
- Direct Input Characters
- Direct Input Control Characters
- Direct Input Code ID/Length
- Read Mode Settings
- Trigger Settings
- Multiple Read Reset Time
- Quiet Zone Settings
- Read Time Settings
- Redundant Decoding Settings
- Positive and Negative Bar Codes
- Buzzer Settings
- Good Read LED
- Diagnostics
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 8
B.) Installation – RS232 Interface
The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary.
There is a power supply jack on the RS-232 connector.
Installation is as follows:
1. Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external power
plug into the jack on the RS-232 connector.
2. Connect the power supply into an electrical outlet (110 V AC)
3. Turn on the power to the host computer. Make sure the communication parameters of the computer match those of the
scanner. The default communications settings are: 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking
4. Be sure the PC is in a program (such as WordPad) that will accept input from the serial port.
Reset All Defaults – RS232
Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most
applications, the scanner will work right out of the box without any need for additional programming. At any time you can return
the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below.
ZZ
Start
Program Menu
-[[-
U2
RS232
-V3-
ZZ
End
Program Menu
-[[-