Scanner User Manual
Table Of Contents
- April 2002
- Part I
- General Information
- Unpacking
- Factory Technical Support
- Part II Installation and SetUp
- A.\) Installation – Keyboard Wedge Interface
- Reset All Defaults – Keyboad Wedge Interface
- Computer Type Selection (for Keyboard Wedge only)
- Intercharacter Delay for Keyboard Wedge interface
- B.\) Installation – RS232 Interface
- Reset All Defaults – RS232
- RS-232C Communication Parameters
- Handshaking Protocol
- Baud Rate
- Data Bits / Stop Bits / Parity
- C.\) Installation – USB Interface
- Reset All Defaults - USB Interface
- Part IIIBar Code Menu Functions
- Section A Programming the Scanner
- Symbology Selection
- Symbology Additions
- Setting the Number of Characters to be Scanned
- UPC Settings
- EAN-13 and EAN-8 Settings
- Code 39 Settings
- Codabar Settings
- MSI/Plessey Settings
- Code 128, EAN 128 Settings
- IATA Settings
- Telepen Settings
- Case Conversion
- Setting a Prefix or Suffix
- Prefix Settings
- Suffix Settings
- Direct Input Keyboard Keys
- Direct Input Characters
- Direct Input Control Characters
- Direct Input Code ID/Length
- Read Mode Settings
- Trigger Settings
- Multiple Read Reset Time
- Quiet Zone Settings
- Read Time Settings
- Redundant Decoding Settings
- Positive and Negative Bar Codes
- Buzzer Settings
- Good Read LED
- Diagnostics
Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 57
Read Mode Settings
ZZ
Start/End
Program
Menu
-[[-
S0
Single
read
-T1-
S1
Multiple
read
-T2-
%
S2
Continuous
read
-T3-
XA
Add-on
wait mode
disabled
-YB-
XB
Add-on
wait mode
0.25 sec.
-TC-
XC
Add-on
wait mode
0.50 sec.
-YD-
%
XD
Add-on
wait mode
0.70 sec.
-YE-
Single Read - When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again
to read another label. This option and "Disable trigger" cannot be programmed at the same time.
Multiple Read - When a bar code has been decoded, the reader will stay ON for a time as set by "read time
settings" or indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the
label has not been detected for a number of scans.
Continuous Read - The reader will produce as much data as it can decode regardless whether it is the same or not.
This mode is mainly used for demonstration and diagnosis.
Add-on Wait Mode - Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a
valid add-on code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found
behind the code, the scanner will transmit the data without add-on. If something is found behind the code, the reader
ignored the code in case it is not a valid add-on.