Scanner User Manual
Table Of Contents
- April 2002
- Part I
- General Information
- Unpacking
- Factory Technical Support
- Part II Installation and SetUp
- A.\) Installation – Keyboard Wedge Interface
- Reset All Defaults – Keyboad Wedge Interface
- Computer Type Selection (for Keyboard Wedge only)
- Intercharacter Delay for Keyboard Wedge interface
- B.\) Installation – RS232 Interface
- Reset All Defaults – RS232
- RS-232C Communication Parameters
- Handshaking Protocol
- Baud Rate
- Data Bits / Stop Bits / Parity
- C.\) Installation – USB Interface
- Reset All Defaults - USB Interface
- Part IIIBar Code Menu Functions
- Section A Programming the Scanner
- Symbology Selection
- Symbology Additions
- Setting the Number of Characters to be Scanned
- UPC Settings
- EAN-13 and EAN-8 Settings
- Code 39 Settings
- Codabar Settings
- MSI/Plessey Settings
- Code 128, EAN 128 Settings
- IATA Settings
- Telepen Settings
- Case Conversion
- Setting a Prefix or Suffix
- Prefix Settings
- Suffix Settings
- Direct Input Keyboard Keys
- Direct Input Characters
- Direct Input Control Characters
- Direct Input Code ID/Length
- Read Mode Settings
- Trigger Settings
- Multiple Read Reset Time
- Quiet Zone Settings
- Read Time Settings
- Redundant Decoding Settings
- Positive and Negative Bar Codes
- Buzzer Settings
- Good Read LED
- Diagnostics
Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 24
Code 39 Settings (continued)
Code 39 is a variable length symbology with an optional check digit ("CD") and printable start/stop ("ST/SP")
characters. The following characters are supported:
•
Numeric characters 0 to 9
•
Alpha characters capital A to Z
•
Special characters - $ / + % and SPACE
•
Start/stop character is *
The checksum is calculated as the sum modulo 43 of the numerical value of the data characters.
In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $
or / with one of the alpha characters (A to Z).
String format:
start
char.
data (0 or
more characters)
check
digit
stop
char.
Options for Code 39:
* Enable full ASCII conversion
* Enable Italian Pharmaceutical conversion
* Enable check digit
* Disable transmission of the check digit
* Enable transmission of start/stop
* Enable leading A for Italian Pharmaceutical
* Selection of the minimum number of data characters
Normal Code 39 - In this mode the decoded data characters are transmitted without further translation.
Full ASCII Code 39 - In this mode the decoded data characters are translated to full ASCII Code 39.
Full ASCII Code 39 if possible - In this mode the decoded data characters are translated to full ASCII code 39.
Invalid combinations are not translated and are transmitted as is.
Concatenation - If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without
the leading space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's
buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 39 bar code bar is transmitted
and the buffer is cleared. The buffer size is reader dependant.