NFT 2100 Miniature High Speed CCD Fixed Position Barcode Scanner User’s Guide Manual No.
Contents Section 1 Introduction and Getting Started Product Overview Quick Start-Up Procedure 1 1 1 Section 2 Technical Specifications Physical Specifications Symbologies Supported Optical Specification Pitch Skew Tilt (rotation) Curvature Electrical Specification RS232 Communications Specifications Connector Pin Outs Environmental Specifications Ordering Information 3 3 3 3 4 4 5 5 6 6 7 7 7 Section 3 Positioning the Scanner Achieving Optimum Performance Measuring Scanner Performance Application Notes
Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon NFT 2100 Fixed Position Scanner. The manual is organized as follows: Section 1 Introduction and Getting Started Describes the general operation of the NFT 2100 scanner. Also provides a Quick StartUp Procedure that allows you to begin using the scanner immediately.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 1 Introduction and Getting Started Product Overview The NFT 2100 Fixed Position Scanner is a miniature, 200 scan per second, CCD barcode reader designed to be easily incorporated into host equipment. The small physical size makes the scanner easy to integrate into any hardware design. Durability and reliability are assured.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner ♦ NFT 2100 CCD Fixed Mount Barcode Click on the ASCII Setup button. In the ASCII Setup Sending screen, select Line ends with line feeds and Echo typed locally so that any keyboard commands you input will appear on your screen. In the ASCII Setup Receiving screen, select Append line feeds to incoming line ends and Wrap lines that exceed terminal width. Click OK. This returns you to the Properties Setting.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 2 Technical Specifications Physical Specifications Case Material Dimensions Weight Cable Length Connector Mounting Steel (Black) 2.16 x 1.85 x 0.78 in (WxDxH) (55 x 47 x 20 mm) 3.5 oz (100 grams) without cable 6.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Skew .5 14 α Aviod this region ±30º α 14 .5 ±10º Specified operation (α) at + 30º or less. (Recommended at + or - 13º) Avoid specular reflection in the dead zone (±10º). Pitch β ±6º Specified operation (β) at + 6º or less.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Tilt (Rotation) 14.5 φ ±10º Specified operation (θ) ±10º or less. (Barcode aspect ratio must allow the field of view to cover all bars). (Recommended operation at 0º) Curvature 35.4 EAN-8 / UPC-E: R = >20 mm (0.8”) or EAN-13 / UPC-A: R => 30 mm (1.2”). Where: PCS 0.9, h = 35.4 mm (1.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Electrical Specifications Operating Voltage +5VDC + 5% Current Operating (LEDs are ON) Idle (LEDs are OFF) Pwr-On Surge 130mA (max) 45mA (max) 1000mA (max) RS232 Communications Specifications RS232 Data Transmission Format Parameter Timing No. of Start Bits No.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Connector Pin-outs 9 Pin D-Sub Female Connector (with power stereo jack) Pin No.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 3 Positioning the Scanner for Optimum Performance Achieving Optimum Performance Four items greatly impact performance: 1) Distance (from the scan window) to the bar code 2) Field of View 3) Specular Reflection 4) Quality of Bar Code Labels 1) Distance to the Bar Code and 'Depth of field' The ideal location of the bar code relative to the scanner is at its focal distance, about 1.4" from the front of the unit.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Readable Width or Field of View for the NFT 2100 (Field-of-View Specification Based Upon 69º Degree Sweep) Distance from Front of Case Field of View 1.0" Focal Distance 1.4" 1.5 2.0" 2.5" 25.4mm 35.4mm 38.1mm 50.8mm 63.5mm 2.6 3.1" 3.3 4.0 4.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Measuring Scanner Performance A method for properly positioning the unit is to program the scanner for Trigger Disable (S7) and Continuous Read (S2) modes. The scanner will now be always on and will continuously read the same bar code. Since the buzzer sounds each time the bar code is read, the sound of the buzzer can be used like a “Geiger counter”. As the position of the scanner changes the sound of the buzzer will change.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur: A bar code is scanned and decoded. A bar code is scanned but is not decoded (e.g.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 4 Configuring the Scanner Since the operation of the NFT 2100 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways. 1. The scanner can be programmed by sending software commands from the host PC to the scanner via the RS232 connection.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 5 Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the NFT 2100 scanner into your application. Our technical support staff is available to answer any questions or work with you to adapt the scanner to your specific situation.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Section 6 Scanner Labeling IEC 825-1 Class 1 LED Devices The NFT 2100 has been examined and found to be a CE Class 1 LED Device according to the relevant requirements of IEC 825-1 and corresponding EN 60825-1 (1993-11) including amendment 1 (1997-09) and amendment 2 (2001-01). The NFT 2100 scanner uses low-power visible LEDs. As with any very bright light source, such as a flashlight, you should avoid staring into the light.
Manual No.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix A Programming the Scanner Two different methods can be used to program parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of these two methods. However, there are certain parameters that are only programmable via the bar code menu. a.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you become proficient at programming you may prefer to change only a few parameters at one time. We recommend that you keep a record of the changes you have made to the scanner. Note, while you are in the programming mode the scanner will not read regular bar codes.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix B Computer Programming Commands All commands listed below must be preceded by an 'ESC' (x1B) or 'STX' (x02) character and be followed by a 'Carriage Return' (x0D) or 'ETX' (x03) character. Shaded areas indicate factory default settings.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 5, IATA, & Codabar Alternate decode algorithm no.1 for Code 39 -Z Enable NFT 2100 CCD Fixed Mount Barcode Disable Options for Code 39 (cont.) Alternate decode algorithm no.2 for Code 39 .
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner Prefix Suffix NFT 2100 CCD Fixed Mount Barcode Select Symbology for prefix/Suffix M5 O5 Codabar (NW-7) M6 O6 Industrial 2 of 5 Direct Input Miscellaneous Characters Select Symbology for prefix/Suffix (cont.) 5A
Manual No.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode YO Margin check 1/7 nominal T4 Disable good read LED (GRL) YP Margin check 2/7 nominal T5 GRL ON for 0.20 seconds after decode YQ Margin check 3/7 nominal T6 GRL ON for 0.40 seconds after decode YR Margin check 4/7 nominal T7 GRL ON for 0.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix C: Bar Code Programming Menus & Commands - Index 1. Global Default & Scanner Configurations....................................... 24 2. Symbology Selection .............................................................. 25-26 3. Add/Activate Specific Bar Code Symbologies ............................ 27-28 4. Delete/Deactivate Bar Code Symbologies...................................... 28 5. Options for UPC..............
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 1.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 2. Symbology Selection Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ A0 Enable all bar code symbologies B1 J0 Enable all UPC and EAN K1 A2 Only Code-39 B3 A3 Only Codabar (NW-7) B! A4 Only IATA B5 A5 Only Code-93 B6 A6 Only Code-128 (Inc.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 2.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 3.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 3. Add/Activate Specific Bar Code Symbologies (continued) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ R6 Enable EAN (13/8) +5 S7 R7 Enable Industrial 2 of 5 S8 % R8 Enable Interleaved 2 of 5 S9 % JZ TriOptic K[ % R9 SCode S: % 4.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 5.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 6.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 7.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 7. Options for Code 39 and IT Pharmaceutical (continued) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ D5 Disable IT Pharmaceutical & enable code 39 E6 D6 Enable IT Pharmaceutical & disable code 39 E7 D7 Enable IT Pharmaceutical if possible E8 DB IT Pharmaceutical, enable transmit of leading A EC DA IT Pharmaceutical, disable transmit of leading A EB % % 8.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 8.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Codabar (NW-7) Format Start Character A.... a.... A.... a.... 1 to 42 data digits Check digit Stop Character ....T ....t ....A ....a • Codabar (NW-7) has four different start/stop character schemes as shown above. The check digit is optional and, if present, would be the last character before the stop character.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 9.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 10.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 11. Options for Code-128 / EAN-128 Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ OF Disable EAN-128 only PG JF Enable EAN-128 only KG MP Disable concatenation NQ MO Enable concatenation NP Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ +W Disable concatenation ,X +V Enable concatenation ,W % % 12.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 13. Setting the Character length that is allowed to be read.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode For example, if a Code 39 label containing 2 characters were scanned in Step 3 then only Code 39 labels would be checked for a minimum length of 2 characters. If a second label had been read in Step 3 (immediately following the first), then that particular symbology would have been set to its associated minimum character length.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Example: To add the alpha character “A” as a Prefix and “B” as a Suffix to UPC-A bar code data: 7. 8. 9. 10. 11. 12.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 15. Setting Prefixes (Identifying the Symbology) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ RY All codes SZ N1 UPC-A O2 M0 UPC-A +2 or +5 N1 N2 UPC-E O3 M1 UPC-E +2 or +5 N2 N3 EAN-13 O! M2 EAN –13 +2 or +5 N3 N4 EAN-8 O5 M3 EAN-8 +2 or +5 N! M4 Code 39 N5 M5 Codabar (NW-7) N6 M6 Industrial 2 of 5 N7 CONTINUED ON NEXT PAGE...
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 15.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 16. Setting Suffixes (Identifying the Symbology) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ RZ All Codes S[ N6 UPC-A O7 O0 UPC-A +2 or +5 P1 N7 UPC-E O8 O1 UPC-E +2 or +5 P2 N8 EAN-13 O9 O2 EAN–13 +2 or +5 P3 N9 EAN-8 O: O3 EAN-8 +2 or +5 P! O4 Code 39 P5 O5 Codabar (NW-7) P6 O6 Industrial 2 of 5 P7 CONTINUED ON NEXT PAGE...
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 16.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 17.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 18.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 19.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 20.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 20.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 21. Direct Input Characters Misc. [[ 5N - 6O (SPACE) 6B 5O . 6P 5B ! 6C 5P / 6Q 5C “ 6D 6A : 7B 5D # 6E 6B ; 7C 5E $ 6F 6C < 7D 5F % 6G 6D = 7E 5G & 6H 6E > 7F 5H ` 6I 6F ? 7G 5I ( 6J 6G @ 7H 5J ) 6K 7A [ 8B 5K * 6L 7B \ 8C 5L + 6M 7C ] 8D 5M , 6N START/END Program Menu (ZZ) [[ (ZZ) START/END Program Menu 5A CONTINUED ON NEXT PAGE...
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 21. Direct Input Characters Misc.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 22.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 22. Communication Parameters. (Continued) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ L5 1 Stop Bit M6 L6 2 Stop Bits M7 % 23 Communication Handshaking.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 23.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 24. Buzzer Operation Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ T0 Volume = Maximum U1 T1 Volume = Upper Mid-range U2 T2 Volume = Lower Mid-range U3 T3 Volume = Minimum U! W0 Disable buzzer X1 W8 Enable buzzer X9 W1 Set buzzer at 3kHz X2 W2 Set buzzer at 3kHz with 2.5kHz interval X3 W3 Set buzzer at 3kHz with 4kHz interval X! W4 Buzzer duration 0.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 25. Setting the Trigger Functions Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ S7 Disable the trigger function /LEDs are ON continuously T8 S8 Enable the trigger function /LEDs are OFF until trigger is activated or “pulled” T9 Z Activate the trigger; turns the scanner ON.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner Mode NFT 2100 CCD Fixed Mount Barcode Trigger Function Enabled (S8) Trigger Function Disabled (S7) After receiving a trigger pulse, scanner will read multiple, different bar codes in succession until it times out. (Each read will reset the scanner’s time out) Scanner will read different bar codes in succession if they are presented to the read window. Scanner may not read the same bar code twice if they are consecutive. (See Sect.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 27. Add-on Wait Mode (Applies to UPC/EAN only) Computer Command Function /Description Bar Code Command (ZZ) START/END Programming Menu [[ XA Disable Add-on wait mode YB XB XC XD Enable Add-on wait mode of 0.25 seconds Enable Add-on wait mode of 0.50 seconds Enable Add-on wait mode of 0.75 seconds YC YD % YE These commands are used when UPC/EAN when add-on is enabled.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 28. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received. In Single Read Mode, the time out is terminated upon a good read. In Multiple Read and Continuous Read Modes the time out period is restarted after any good read.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 29. Multiple Read Reset Time This option is used in conjunction with the multiple read mode. The selected time sets the period the scanners should be pointed away from a label before that same label can be decoded again. Indefinitely means that the next bar code must always be different during the time the scanner is triggered.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 30. Quiet Zone Options With this option the scanner can decode bar codes that have smaller quiet zone margins than specified for the symbology. Be careful when using this option as its use may increase the possibility of partial and ghost reads. Do not use smaller margin checks than necessary. If possible, replace the bar codes labels with others that have the correct quite zone margins.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 31. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has completed three consecutive, identical “good reads”.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode 33. No read error messages. The scanner can be programmed to transmit an error message when no barcode is read. The unit must be in trigger mode, then, the error message will be sent at the end of a trigger time out. 2 types of messages can be sent. The first type will indicate that no label was present or that nothing was in front of the scanner.
Manual No.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix E: NFT 2100 – Optical Performance NFT 2100 Depth of Field Table (Grade A Labels) Density Min. Distance (inches) Max Distance (inches) Range (inches) 6 mil 0.9 1.6 0.7 10 mil 0.8 1.7 0.9 20 mil 0.8 2.0 1.2 40 mil 0.9 2.4 1.5 NFT 2100 Depth of Field Chart Focal Distance 1.4" (35.4 mm) 6 Mil 10 Mil 20 Mil 40 Mil 0 0.5 1.0 1.5 2.0 Distance from front of scanner case (inches) 2.5 3.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix F: Placement Drawing (All dimensions in millimeters [inches]) This Drawing shows one possible placement of the scanner relative to the target label. Other orientations are possible depending on barcode density and barcode length. Please use the optical information provided in appendix E as guidance.
Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner NFT 2100 CCD Fixed Mount Barcode Appendix G: Placement Drawing for test tubes (All dimensions in millimeters [inches]) This Drawing shows one possible placement of the scanner relative to the target label. Other orientations are possible depending on barcode density and barcode length. Please use the optical information provided in appendix E as guidance.
Manual No.